14
11. PREPARATION FOR STORAGE (See Fig. 󱯘)
12. TROUBLESHOOTING
The following procedures should be followed prior to storage of your generator for periods of 6 months or longer.
Drain fuel from fuel tank carefully by disconnecting the fuel line.
Gasoline left in the fuel tank will eventually deteriorate making engine-starting dif cult.
When draining fuel from the fuel tank, use the hand pomp and set it into the re lling port. (See Fig. 󱯘-)
Remove the drain screw of the carburetor. (See Fig. 󱯘-)
DRAIN SCREW
Change engine oil.
Check for loose bolts and screws, tighten them if necessary.
Clean generator thoroughly with oiled cloth. Spray with preservative if available.
NEVER USE WATER TO CLEAN GENERATOR !
Pull starter handle until resistance is felt, leaving handle in that position.
Store generator in a well ventilated, low humidity area.
When generator engine fails to start after several attempts, or if no electricity is available at the output
socket, check the following chart. If your generator still fails to start or generate electricity, contact your
nearest Robin dealer or service shop for further information or corrective procedures.
Check if engine switch is in its proper position. Turn engine switch to " "(CHOKE) position.
When Engine Fails to Start:
When No Electricity Is Generated at Receptacle:
Check if the DC circuit breaker
is turned OFF.
Check if the Overload Lamp
is turned ON (Red).
Check AC receptacle and DC terminals for
loose connection.
Check to see if engine starting was
attempted with appliances already
connected to generator.
Depress the circuit breaker into ON position,
after making sure the electric appliances
are in the normal condition.
Stop the engine and check the appliances
and/or generator for overloading.
Check and clean spark arrester if clogged.
Secure connection if necessary.
Turn off switch on the appliance, and
disconnect cable from receptacle. Reconnect
after generator has been started properly.
Check fuel level.
Check to make sure generator is not
connected to an appliance.
Check spark plug for loose spark plug cap.
Check spark plug for contamination.
Check engine oil level.
Check if the recommended spark plug
would be adopted.
If empty, refill fuel tank making sure not to overfill.
If connected, turn off the power switch on the
connected appliance and unplug.
If loose, push spark plug cap back into place.
Remove spark plug and clean electrode.
If the engine oil level is low, add the oil to the
upper level line on the oil gauge.
If not, replace with the recommended spark plug.
If the recommended spark plug is not available
by all means, make sure to replace with
equivalent one of resistance type.
R1700igenGU7322.indd14R1700igenGU7322.indd14 2011/11/2113:34:222011/11/2113:34:22

Other manuals for Robin R1700i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Robin R1700i and is the answer not in the manual?

Robin R1700i Specifications

General IconGeneral
BrandRobin
ModelR1700i
CategoryPortable Generator
LanguageEnglish

Related product manuals