EasyManuals Logo

Robin RGV2800 User Manual

Robin RGV2800
45 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #34 background imageLoading...
Page #34 background image
29
ENGLISH
COVER
INNER
ELEMENT
OUTER
ELEMENT
1. Urethane Foam Element
Wash and clean the urethane foam with detergent. After cleaning, dry it.
Clean the urethane foam element every 50 hours.
2. Paper element
Clean by tapping gently to remove dirt and blow off dust.
Never use oil. Clean the paper element every 50 hours of operation, and
replace element set every 200 hours.
Clean and replace air cleaner elements more often when operating in dusty
environments.
Do not wash elements with
kerosene, gasoline or oil.
CAUTION
A dirty air cleaner element will cause
starting difficulty, power loss, engine
malfunctions, and shorten engine life
extremely. Always keep the air cleaner
element clean.
(Model RGV4100, 6100)
CLEANING AND ADJUSTING
SPARK PLUG
(a) If the plug is contaminated with
carbon, remove it using a plug cleaner
or wire brush.
(b) Adjust the electrode gap
.
ELECTRODE GAP
Electrode gap
Model Spark plug
RGV2800
RGV4100
NGK BR6HS
RGV6100 NGK BR6ES
Electrode gap
0.02 to 0.03 in.
(0.6 to 0.7 mm)
0.03 in.
(0.7 to 0.8 mm)
RGV28-61(CSA)英取説GU203104.10.286:55PMページ29

Other manuals for Robin RGV2800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Robin RGV2800 and is the answer not in the manual?

Robin RGV2800 Specifications

General IconGeneral
BrandRobin
ModelRGV2800
CategoryPortable Generator
LanguageEnglish

Related product manuals