15
−
TABLE 1
NOTE :
When the no-fuse breaker turns off during operation, the generator is over loaded
or the appliance is defective. Stop the generator immediately, check the appliance
and / or generator for overloading or detect and have repaired as necessary by
Robin dealer or service shop.
■
To take power out from the TWIST
LOCK RECEPTACLE, insert the
plug into the receptacle, and turn
it clockwise to the lock position.
■
Be sure to ground the generator if
the connected electrical device Is
grounded.
WARNING
TWIST
The duplex 120V receptacle is protected by a GFCI (Ground Fault Circuit
Interrupter). GFCI shuts off the output current from the duplex 120V
receptacle when a ground fault occurs in the generator or the appliance.
Please note that other receptacles are not protected by GFCI.
[
CAUTION
]
up to 30A
up to 20A
up to 20A
NEMA
5-20A
NEMA
L5-20R
NEMA
L14-30R
NEMA
5-20P
NEMA
L5-20P
NEMA
L14-30P
GFCI (Ground Fault
Circuit Interrupter)
Receptacle, duplex
(REC1)
Locking Receptacle
(REC2)
Locking Receptacle
(REC4)
Style Ampere Receptacle AC plug Description
up to 30A
NEMA
L5-30R
NEMA
L5-30P
Locking Receptacle
(REC3)
RGV7500RAi取説GU201805.4.41:25PMページ15