EasyManua.ls Logo

Roca TECNO 28-GM - Technical Data; Accessories

Roca TECNO 28-GM
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
TECHNICAL DATA
(1) Reference conditions: Ambient temperature 20°C - Barometric pressure 1000 mbar - Altitude 100 m a.s.l.
(2) Pressure at test point 8)(A)p.6, with zero pressure in the combustion chambre, with open gas ring 2)(B)p.14 an maximum burner output
(2) Sound pressure measured in manufacturers combustion laboratory, with burner operating on test boiler and at maximum rated output.
ACCESSORIES
(optional):
KIT FOR LPG OPERATION:
The kit allows the TECNO 28-38-50-GM burners to operate on LPG.
OUTPUT POWER REGULATOR KIT:
Under modulating operation, the burner automatically adapts to one of an infinite number of firing rates
between the low and high flame output position, thus ensuring stable operating conditions in terms of temperature or pressure. Two components
should be ordered: • Power regulator to install to the burner; • probe to install to the boiler.
GAS TRAIN ACCORDING TO REGULATION EN 676 (with valves, pressure governor and filter):
see page 17.
MODEL
TECNO 28-GM TECNO 38-GM TECNO 50-GM
OUTPUT
(1)
MAX.
kW 163 - 325
140 - 280
232 - 440
200 - 378
290 - 580
249 - 499Mcal/h
MIN.
kW 52
45
70
60
85
73Mcal/h
FUEL NATURAL GAS: G20 - G21 - G22 - G23 - G25
G20 G25 G20 G25 G20 G25
- Net calorific value
kWh/Nm
3
Mcal/Nm
3
10
8,6
8,6
7,4
10
8,6
8,6
7,4
10
8,6
8,6
7,4
- Absolute density
kg/Nm
3
0,71 0,78 0,71 0,78 0,71 0,78
- Max. delivery
Nm
3
/h
32 38 44 51 58 68
- Pressure at max. delivery
(2)
mbar 7,5 11,1 6,6 9,7 7,2 10,6
OPERATION
On-Off (1 stop min each 24 hours).
This burner is also fitted for the continuos operation, if it is equipped
with the control box LANDIS type LGK 16.333 A27 (interchangeable
with the burner control box Landis LFL 1.333).
Progressive two-stage or modulating by kit (see ACCESSOIRES).
STANDARD APPLICATIONS Boilers: water, steam, diathermic oil
AMBIENT TEMPERATUR °C 0 - 40
COMBUSTION AIR TEMPERATURE °C max 60
ELECTRICAL SUPPLY
V
Hz
230 ~ +/- 10%
50 - single-phase
230 - 400 with neutral ~ +/- 10%
50 - three-phase
ELECTRIC MOTOR rpm
W
V
A
2800
250
220 - 240
2,1
2800
450
220/240 - 380/415
2 - 1,2
2800
650
220/240 - 380/415
3 - 1,7
MOTOR CAPACITOR µF / V 8/450
IGNITION TRANSFORMER
V1 - V2
I1 - I2
230 V - 1 x 8 kV
1 A - 20 mA
ELECTRICAL POWER CONSUMPTION W max 370 560 750
ELECTRICAL PROTECTION IP 44
IN CONFORMITY WITH EEC DIRECTIVES 90/396 - 89/336 - 73/23 - 92/42
NOISE LEVELS
(3)
dBA 68 70 72
APPROVAL CE 0085AQ0709
COUNTRY
CATEGORY
IT-AT-GR-DK-FI-SE
II
2H3B/P
ES-GB-IE-PT
II
2H3P
NL
II
2L3B/P
FR
II
2Er3P
DE
II
2ELL3B/P
BE
I
2E(R)B,
I
3P
LU
II
2E3B/P
BURNER
TECNO 28-GM TECNO 38-GM TECNO 50-GM
OUTPUT kW 95 ÷ 325 115 ÷ 440 140 ÷ 580
Blast tube lenght mm 216 351 216 351 216 351
Code 143040116 143040122 143040117 143040123 143040118 143040124
PARAMETER TO BE CHECKED
PROBE POWER REGULATOR
Range Type Code Type Code
Temperature - 100...+ 500°C PT 100 -
RWF40 143040159
Pressure
0...2,5 bar
0...16 bar
Output probe
4...20 mA
-
Important:
The installer is responsible for the addition of any safety device not forseen in the present manual.
GB
ATC ROC