EasyManua.ls Logo

Rockwell Automation STRATIX 8000 1783-MS06T - Page 35

Rockwell Automation STRATIX 8000 1783-MS06T
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Publication 1783-UM002C-EN-P - April 2009 35
Chapter 2
Install the Switch on a Wall or Panel
The switch can be installed on a wall or a panel. To attach the switch to a wall
or a panel, follow these steps.
1. If the DIN rail latches are pushed out, push them in so they are fully
locked in place.
2. Rotate all feet to their recessed positions so that the switch can mount
flat on the wall or panel.
IMPORTANT
If you are installing expansion modules, attach the expansion
modules to the switch before mounting the switch.
TIP
You will need M5 or #10-24 or #10-32 bolts or screws with 1.27
cm (0.5 in.) O.D. flat washers. This hardware is not provided
with the switch.
31777-M
TIP
If greater air circulation around the switch is required, rotate
the feet to their extended positions before mounting the switch
on the wall.

Table of Contents

Related product manuals