LOW VOLTAGE INPUT
SWITCHING
8
7
2
RUN JUMPER INPUT
FC-90 PLUS SERIES TB2
,
INPU
T
LOW CURRENT SWITCH
8
7
FC-90 PLUS SERIES TB2
-
1
8
9
9
7
9
C)
5-30 VDC INPUT VOLTAGE
OFF/ON CONTROL
(DC Voltage from PLC)
FC-90 PLUS SERIES TB2, OUTPUT
P/N 24-490/24-491
FEEDER BOWL/HOPPER
INTERLOCK
FC-90 PLUS SERIES TB2
B)
A)
+
S1
Wh #20
100K
4-20
LINE VOLTAGE
AUX FEATURE
+
(TALL)
3
CONTROL
TB1
TERM. STRIP
+
+
On
SW6
11
3
Norm
12
SW9
Wh #14
6
HOT
COM
JUMPER
P/N 111-500
Wh #14
5
Max
1/8W MIN
NPN
CFR SENSOR
Option 123-170
6
SW3
120
Wh #14
Sig.
BLU
-
TB1
8
Wh #14
HOT
9
Unit B
60 Rev
-
External
OPTIC SENSOR
1
TB1
MAIN
OUTPUT POWER
Yl #20
9
Vi #20
SIG
Interlock Input
Min
-
(TALL)
AC HOT
4
TERM. STRIP
TRIAC
INPUT POWER
12
SW4
-
COM
A2
-
AUX
CFR
Wh #20
12 2
Wh #14
LINE VOLTAGE
TRANSFORMER
+
4-20mA
+
12 9
S
+
FUSE
5
Bl #14
AUX FEATURE
Direct
OPTICS
SW8
6
G
Min
S1
Br
5
(SMALL)
Bl #14
1/8W MIN
ACCEPTS BOTH OPTIC AND PROX SENSORS, NPN OR PNP.
-
Off
8
5
JUMPER
POT
COM
P/N 24-490
8
Soft
+
J1
CHASSIS
SENSOR OPTION
2
SIG
+
Bl #14
HOT
8
-
TB2
+
SM312FP1H
Vi #20
1 10
S
RUN
COM
11
Pot Input
RUN
TB2
GATE
SIG
FUSE
CONTROL
7
TB2
AC COMMON
Inv
A2
11 1
Independent
G
cw
A1
Rd #20
Master
(SMALL)
9
60
TERM. STRIP
POWER
60
Or #14
H1
Unit A
TB2
3
PNP
100K
Bl #14
4
RUN
MAIN
-
BLK
LVC
LOAD
6
Or #14
11
Bu
7
GND
SW5
OUTPUT POWER
POT
CONNECT SINK OR SOURCE WIRE TO "SIG" INPUT
Pot Input
H1
SW10
Soft
CHASSIS
PNP
7
TERM. STRIP
+
TB1
AC HOT
BRN
TRANSFORMER
10
2
-
GND
10
Max
AC COMMON LOAD
1
BANNER
POWER
120
4
Bl #14
NPN
SW7
GATE
GND
Bl #14
10
HOT
4-20mA
Interlock
TRIAC
RUN
P/N 24-210
Bl #14
cw
-
7
1
A1
OFF/ON CONTROL GUIDE
10-30 VDC INPUT VOLTAGE
10
10
FC
-
40 PLUS SERIES TERM STRIP TB
-
2
9
SWITCH
7
2
6
6
5
11
(DC Voltage from PLC or FC-90 Plus)
LOW CURRENT
SWITCH
B)
9
FC-40 PLUS SERIES TERM STRIP TB-2
10
11
FEEDER BOWL/HOPPER INTERLOCK
LOW VOLTAGE INPUT SWITCHING
6
FC-90 PLUS SERIES
5
12
PADDLE
C)
See section 6 of the Application Note for more
details on the REMOTE OFF/ON CONTROL guide.
FC-40 PLUS SERIES TERM STRIP TB-2, INPUT
OFF/ON CONTROL
A)
12
8
8
J1
P/N 24-210/24-211
7
-
12
TERM STRIP TB-2, OUTPUT
1
+
8
11
5
9
7
RODIX INC.
FEEDER CUBE
FC-90 Plus Series
WIRING DIAGRAM
MODEL INPUT VAC AMPS OUTPUT
FC-92 PLUS 120 VAC 10/5 0-120
RODIX, INC.
Toll Free (800) 562-1868, FAX (815) 316-4701
Email custserve@rodix.com
www.rodix.com
FC-92.docx 2/16/2018 Page 2