6 Light signals and output contacts
Theoutputcontactsarenormallyclosedandwhentheyneedtosignalsomethingtheyopen.
The3erroralertLEDs usually blinkonce to show operatingstatusand they switch offwhen they need to signal
something.
AUTOMATION STATUS TO LED (GREEN) TC LED (RED) ALR LED (RED) TO TC ALR
Intermediate position Presence Presence ...... Closed Closed ......
Fullopening Off Presence ...... Open Closed ......
Fullclosure Presence Off ...... Closed Open ......
Control unit in alarm ...... ...... Off ...... ...... Open
Control unit not in alarm ...... ...... Presence ...... ...... Closed
EachtimeB73/LTMisswitchedon(orrestarted),theRGBheadandboomlightsperformarapidswitch-onsequence:
red–green–blue.
7 Adjusting the parameters on the CTRL control unit (FW version
P4.30 or later)
NOTE:R=red,G=green,B=blue
-white headlights:factory-installedmodel
-RGB head lights: BI/BLED/4/C, BI/BLED/6/C, BI/BLED/8/C
-R boom lights: ALED/4C, ALED/6C, ALED8C, ALED/12C
-RGB boomlights:ALED/4C/RGB,ALED/6C/RGB,ALED/8C/RGB,ALED/12C/RGB
The operation of the B73/LTMboardismanagedbyparameter10oftheCTRLcontrolunit.
10 00
Enabling the B73/EXP signalling device for fully open/closed barrier signalling (N.C. pure
contact) and B73/LTM for RGB boom trafc lights management
00
Disabled(noaccessorydevicetocontrol).
01
B73/EXPenabled.
Withtheboomfullyopen,theTO(N.C.)contactopensandthegreenLEDontheB73/EXPboardlightsup.
Whentheboomiscompletelyclosed,contactTC(N.C.)opensandtheredLEDilluminatesontheB73/EXP
board.
02
B73/LTM:R/Gheadlight,Rboomlights(ALED/4C-ALED/6C-ALED/8C-ALED/12C)
03
B73/LTM:whiteheadlight(BI/BLED),RGBboomlights
04
B73/LTM:R/Gheadlight,RGBboomlights
05
B73/LTM:headlightcontrolledbytheIN_SEL(*)input,Rboomlights(ALED/4C-ALED/6C-ALED/8C-
ALED/12C)
06
B73/LTM:headlightcontrolledbytheIN_SEL(*)input,RGBboomlights
07
B73/LTM:openIN_SELinput,managedbythetwilightsensor,keepstheheadandboomlightsoffduringtheday
08
B73/LTM:openIN_SELinput,managedbythetwilightsensor,keepstheboomlightsoffduringtheday
09
B73/LTM:openIN_SELinput,managedbythetwilightsensor,keepstheheadlightsoffduringtheday
(*)closedcontact:greenheadlight;opencontact:redheadlight
18 00
Boom RGB light error alert selection when unlocked and fully open
Iftheboomisunlockedformaintenance,itispossibletohighlightthattheautomationsystemisnot
operational.
NOTE:theparameterisonlyvisibleiftheRGBboomlightmanagementhasbeenselectedatparameters10,
70, 72, 74, 75, 79
00
RGBstandardmanagement
01
Boom lights switched off
02
Greenboomlights,presenceashing
03
Greenboomlights,switchedon
70 00
Operating modes of the head LED light
(seetypedescriptions,chapter5)