Security Locks SL2000E v1.2 EN Rev.A.doc 2011-09-01
Page 4 of 11
USER Codes
These codes are used for activation of the Door Relay output. Each time a valid USER code is entered the
SL2000 starts counting C1C2 time delay and then when it passes by the unit activates Door Relay output. The
Door Relay output is activated for time defined by C3C4 settings. The USER codes can be 2-8 digits long.
Commands
Commands can be entered during normal working time of a SL2000 code lock and doesn’t require entry to the
programming mode.
[USER Code] [#]
Whenever a valid USER code is entered the code lock generates two beeps (**) and then starts count C1C2
time delay. After it passes by the SL2000 activates Door Relay output for time defined by C3C4 settings. During
this time door locking device is energized and user can open the door.
[MASTER Code] [#]
Each time the MASTER code is entered the SL2000 changes its arming mode (switches from Armed to Disarmed
mode or in reverse direction).
[INSTALLER Code] [#]
After this command code lock generates two beeps (**) and enters the Installer Programming mode. In this
mode installer can program the USER codes to a unit.
[*] [Old INSTALLER Code] [#] [New INSTALLER Code] [#]
This command erases the old INSTALLER code and program new INSTALLER code. If command is successfully
accomplished the unit generates three series of two beeps (** ** **).
[*] [Old MASTER Code [#][New MASTER Code] [#]
This command erases the old MASTER code and program new MASTER code. If command is successfully
accomplished the unit generates three series of two beeps (** ** **).
[Bell Key]
A single short press of this key activates the Aux output and internal buzzer for a time of ~2…3 seconds. The
indication on Aux output and buzzer is continued for entire time as long as Bell key is being pressed.
[#]
Normally it marks the end of a code but when pressed separately for a time longer the 0.5s it acts in the same
way as Bell key.
Programming of the USER Codes
The SL2000 enables programming of up to 55 different USER codes. The USER codes can be managed
(added/deleted/changed) only in the Installer Programming mode. In order to program the USER codes you
must first enter the Installer Programming mode and the you have access to the programming commands listed
below:
[0] [1] [#] [code] [#] - Programming of the USER code no. 1
[0] [2] [#] [code] [#] - Programming of the USER code no. 2
[0] [3] [#] [code] [#] - Programming of the USER code no. 3
...etc.
...etc.
...etc.
[5] [5] [#] [code] [#] - Programming of the USER code no. 55
[0] [0] [#] - Delete all USER codes
[9] [9] [#] [code] [#] - Deletes the code entered in square brackets
Note: The SL2000 enables programming of maximum 55 USER codes, each of them can open the door.
Note: Whenever you re-program MASTER or INSTALLER code remember that new code programmed into a unit
must have the same length as the old one.