Security Locks SL2000E v1.2 EN Rev.A.doc 2011-09-01
Page 6 of 11
Option 2: Disable USER Codes When in Armed Mode
C9: Defines the length of the USER codes, enter 0-3, (default: 1).
0 : USER codes are 2 digits long
1 : USER codes are 4 digits long
2 : USER codes are 6 digits long
3 : USER codes are 8 digits long
C10: Defines the length of the MASTER and INSTALLER codes, enter 0-3, (default: 1).
0 : Both codes are 4 digits long
1 : Both codes are 6 digits long
2 : Both codes are 8 digits long
3 : Both codes are 10 digits long
If an illegal operation occur during Memory Reset the device will signal an error (long beep) and will return to
the beginning of the programming so you can start to enter the C1-C10 digits once again. The Memory Reset
procedure automatically comes to an end when the last (C10) digit is entered. The device stores the
configuration as well as all codes in a nonvolatile memory which can be reprogrammed whenever required.
After the Memory Reset procedure comes to an end all codes are set to default values (see section Default
Codes).
Example:
The following digits C1-C10 were entered during the Memory Reset procedure: [0][1][0][2][3][3][1][0][2][3]
This sequence sets the following options:
· Open Delay: 01 second
· Lock Activation Time: 02 seconds
· Time for Door Closing: 33 seconds
· Reprogramming of the MASTER code: disabled
· Reprogramming of the INSTALLER code: enabled
· Option 1; Timed Lock-out : option off
· Option 2; Disable Access in Armed Mode: option off
· USER codes: 6 digits
· MASTER and INSTALLER codes: 10 digits
Default Codes
After the Memory Reset is accomplished the following codes are automatically programmed into a unit:
MASTER Code
All digits are “1” (1111…), the length of the code depends on the C10 parameter entered during Memory Reset
procedure.
INSTALLER Code
All digits are “2” (2222…), the length of the code depends on the C10 parameter entered during Memory Reset
procedure.
USER Code no 01
All digits are “3” (3333…), the length of the code depends on the C9 parameter entered during Memory Reset
procedure.
USER Code 02..55
All USER codes no 02 -55 are blank (they doesn’t exist).