How to fix a Rogers KI-25-125 that fails to start?
- MmorgansamanthaAug 17, 2025
If your Rogers Air Compressor isn't starting, there are several potential causes. First, ensure the power is turned “ON” by closing the main disconnect. Check for blown fuses in the control circuit or the 460-volt Phase Protector and replace them after correcting the cause. See if the high air temperature switch is open. Overload relays might have tripped; reset them after addressing the overload condition, then press the reset keypad. Inspect the starter contactor for malfunctions, burnt contacts, or loose connections. Verify the incoming power supply and check pressure, temperature switches, or remote devices for defects. Ensure all wire connections are tight, and examine the 120 VAC and 24 VDC power supply. Reset any alarms and wait for the Start Delay Timer to finish counting down.