R&S
®
FSH3 and R&S
®
FSH6 Data Sheet  
1145.5973.12 TI.1  E-11 
Specifications 
Specifications are valid under the following conditions: 15 minutes warm-up time at ambient 
temperature, specified environmental conditions met and calibration cycle adhered to. Data without 
tolerances: typical values. Data designated as "nominal": design parameters, i.e. not tested. 
 
Specification  Condition  R&S
®
FSH3  R&S
®
FSH6 
Frequency 
     
Frequency range    100 kHz to 3 GHz  100 kHz to 6 GHz 
Reference frequency       
 Aging    1 ppm/year 
 Temperature drift 
0 °C to 30 °C 
30 °C to 50 °C 
2 ppm  
in addition 2 ppm/10 °C  
Frequency counter     
 Resolution    1 Hz 
Frequency span    0 Hz, 100 Hz to 3 GHz  0 Hz, 100 Hz to 6 GHz 
Spectral purity 
     
SSB phase noise 
f = 500 MHz,  
20 °C to 30 °C 
   
  30 kHz from carrier    <85 dBc (1 Hz) 
  100 kHz from carrier    <100 dBc (1 Hz) 
  1 MHz from carrier    <120 dBc (1 Hz) 
Sweep time  span = 0 Hz  1 ms to 100 s 
  span > 0 Hz  20 ms to 1000 s, min. 20 ms/600 MHz 
Bandwidths     
 Resolution bandwidths 
 (-3 dB) 
1145.5850.13  1, 3, 10, 30,100, 200, 300 kHz, 1 MHz 
 
1145.5850.03, .23,  
1145.5850.06, .26 
in addition 100 Hz, 300 Hz 
 Tolerance 
≤300 kHz  ±5 %, nominal 
  1 MHz 
±10 %, nominal 
 Resolution bandwidths 
  (-6 dB) 
with option R&S
®
FSH-K3 
installed 
in addition 200 Hz, 9 kHz, 120 kHz 
     
 Video bandwidths    10 Hz to 1 MHz in 1, 3 steps 
 
 
Amplitude 
   
Display range 
  average noise level displayed to +20 dBm 
Maximum permissible DC 
voltage at RF input 
 
50 V/ 80 V 
1
) 
Maximum power 
  20 dBm, 30 dBm (1 W) for max. 3 minutes 
Intermodulation-free dynamic 
range 
third-order IM products, 
2 x -20 dBm, reference 
level = -10 dBm 
typ. 66 dB  
(+13 dBm third-order intercept) 
 
   
1
 80 V valid as of serial number 100900 (model 1145.5850.03) or 101600 (model 1145.5850.13); models 1145.5850.23, 1145.5850.06 and .26 all serial numbers.