Power measurements on TDMA signals  R&S FSH 
1145.5973.12 4.44  E-11 
Power readout 
The R&S FSH displays the measured power at the bottom of the measurement diagram (Power = 
nn.n dBm). Usually the trace is not obscured. However, if the trace is in this area of the screen, the 
power readout can be removed from the screen. Simply press the PWR DISP ON/OFF softkey. If the 
softkey label is highlighted in green, the power readout is on. 
 
Setting the trigger 
A trigger is usually required to perform power measurements on bursts. In the default setting, the 
R&S FSH is configured to use the video trigger at 50 % of the Y scale on the measurement diagram. 
Assuming that the burst on which the measurement is to be made crosses the 50 % point of the trigger, 
the R&S FSH will trigger on the rising edge of the burst. 
Should this not be the case, the trigger level must be adjusted so that the R&S FSH is triggered by the 
burst edge. Otherwise no measurement will be performed. 
If the DUT has a trigger facility, the external trigger can also be used for the measurement. 
 
 Connect the DUT’s trigger output to the 
R&S FSH’s trigger input. 
 Press the SWEEP key. 
 Press the TRIGGER softkey. 
 Select the EXTERN menu item (rising or falling 
edge). 
 Confirm your selection with the ENTER key or the 
TRIGGER softkey. 
Select the appropriate trigger delay to position the 
burst in the measurement window. 
 Press the DELAY... softkey. 
 Using the rotary knob or the cursor keys, adjust the 
trigger delay until the TDMA burst is inside the 
vertical lines indicating the measurement range, or 
 Using the number keys, enter the appropriate 
trigger delay and terminate the entry with the 
appropriate unit key.