Contents R&S FSH
1145.5973.12 I.6 E-11
Using the R&S FSH in receiver mode ......................................................................................... 4.61
Setting the frequency............................................................................................................... 4.62
Setting the reference level....................................................................................................... 4.64
Setting the bandwidth.............................................................................................................. 4.65
Setting the detector.................................................................................................................. 4.66
Setting the measurement time................................................................................................. 4.66
Measurement on multiple frequencies or channels (scan)...................................................... 4.67
Measurements using the power sensor ..................................................................................... 4.69
Connecting the power sensor.................................................................................................. 4.69
Zeroing the power sensor........................................................................................................4.71
Selecting the unit for the power readout.................................................................................. 4.72
Setting the averaging time....................................................................................................... 4.73
Taking additional loss or gain into account ............................................................................. 4.73
Measuring forward and reflected power..................................................................................... 4.75
Zeroing the power sensor........................................................................................................4.77
Setting the power measurement weighting ............................................................................. 4.78
Selecting the unit for the power readout.................................................................................. 4.79
Taking additional attenuation into account.............................................................................. 4.80
Two-port measurements with the tracking generator............................................................... 4.82
Measuring the transmission of two-ports................................................................................. 4.84
Vector transmission measurement............................................................................. 4.87
Transmission measurement using the connected VSWR Bridge R&S FSH-Z3 ........ 4.89
Spectrum measurements with the VSWR Bridge R&S FSH-Z3 or R&S FSH-Z2
connected ................................................................................................................... 4.90
Settings for detection of the R&S FSH-Z3 in transm. and spectrum measurements. 4.91
Supplying DC voltage to active DUTs ........................................................................ 4.91
Reflection measurements........................................................................................... 4.91
Scalar measurement of reflection............................................................................... 4.92
Vector measurement of reflection............................................................................... 4.94
Display of reflection in vector measurement ............................................... 4.96
Spectrum measurements with the VSWR Bridge R&S FSH-Z3 or R&S FSH-Z2
connected ................................................................................................................. 4.100
Settings for detection of the R&S FSH-Z2 and R&S FSH-Z3................................... 4.101
One-Port Measurement of Cable Loss...................................................................................... 4.102