EasyManuals Logo

Roland RML-1 User Manual

Roland RML-1
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
RML-1 PROGRAMING GUIDELINE
- 14 -
Similar to VS.
V (Velocity Z axis -- Tool up/down speed setting command)
<Format>
V tool-up/down speed [terminator]
V [terminator]
<Type>
Basically int
float for noninteger values such as V 0.5
<Parameter Range>
-32768 32767 [mm/sec]
<Description>
This sets the speed relationship when the tool moves along the Z axis or
when movement is performed using the three-axis simultaneous-
movement command.
V without a parameter is set to the default speed.
When a parameter is present and is a settable speed, the speed is set to
the value of the parameter.
When the parameter is not a settable value, the maximum or minimum
settable value is set automatically.
<Errors>
An out-of-range parameter results in error 3.
When the parameter is within range, no error occurs even if its value
cannot be set on the particular model.
W (dwell -- Dwell specification command)
<Format>
W dwell-time [terminator]
W [terminator]
<Type>
int
<Parameter Range>
0 to 32,767 msec
<Description>
When a parameter is given, if it is a settable value, then dwell (waiting) for
the time set by the value is performed when the cutting direction changes.