14
SEP.2005
CHECKING THE VERSION
NUMBER
1.
Turn of the power.
2.
Simultaneously hold down the [MARK] switch and press the [POWER]
switch.
3.
The version is indicated in the display.
* Ver 1.01 is indicated in the 7’SEG LED as “101”.
USERS DATA SAVE AND
LOAD
Saving Backup Data (Backup
Save)
Here’s how to save backup data (all of the SP-404’s data including
sample banks and pattern banks) to a memory card. You can save up
to twelve sets of backup data.
If the card runs out of free space because you save large
amounts of sample or pattern data, the number of backup sets
that can be saved will be fewer.
1.
Insert a memory card formatted for the SP-404 in the SP-404 and turn on
the power.
2.
Hold down [CANCEL] and press one of the BANK [C/G]-[F/J] buttons.
“SAV(SAU)” appears in the display and pads for which backup data has
not been saved begin blinking.
3.
Select one of the flashing pads as the save destination pad. The selected
pad remains lit, and the other pads stop flashing and remain off.
[REC] flashes.
4.
Press [REC].
[REC] lights, and the Backup Save operation begins. The dot in the
display will blink while the operation is in progress.
When saving is complete, the blinking will stop.
Never turn off the power while the dot is blinking. Doing so may damage the
backup data or the memory card.
5.
Turn off the power and keep the memory card safely stored.
Loading Backup Data (Backup
Load)
Here’s how to load backup data (all of the SP-404’s data including sample
banks and pattern banks) from a memory card.
When you execute the Backup Load operation, the internal settings of the SP-
404 will be erased and replaced by the backup data you loaded.
Backup Load cannot be performed if data protect is in effect. Before starting
the procedure, hold down [CANCEL] and turn on the power to cancel data
protection
1.
Insert the memory card containing the backup data in the SP-404 and turn
on the power.
2.
Hold down [CANCEL] and press BANK [A] or [B].
“Lod” appears in the display and the pads for which backup data has
been saved begin blinking.
If the Protect setting is enabled, “Prt” (Protected) appears in the display, and
you will be unable to execute the Backup Load operation.
3.
Press a pad to select the backup data that you want to load.
The selected pad lights, and the other pads stop blinking.
[REC] begins blinking.
You can’t select a pad that was dark in step 2 (i.e., a pad for which no data has
been saved). If you decide to cancel the operation at this point, press
[CANSEL].
4.
Press [REC].
[REC] lights, and the Backup Load operation begins. The dot in the
display will blink while the operation is in progress. When loading is
complete, the blinking will stop.
Never turn off the power while the dot is blinking. Doing so may damage the
backup data or the memory card.
Instructions for System
Initialize
Factory Settings Cannot Be Restored
with SP-404 Alone
Once samples or patterns assigned at the factory have been deleted or
changed, the SP-404 factory settings cannot be restored using the instrument
itself. To return the SP-404 to its factory settings, obtain the SERVICE DATA &
PROGRAM CD-ROM (#17041673) and after confirming the service
information, create an “initialization memory card” and proceed with the
initialization.
Main Process
1.
Connect the memory card formatted for the SP-404 to the computer.
2.
Copy the data on the SERVICE DATA & PROGRAM CD-ROM through
the computer to the initialization memory card.
3.
Connect the memory card with the data copied to it to the SP-404 and
restore the SP-404’s settings.
* For more detailed instructions, refer to the following pages.
Required Equipment
1.
SP-404 SERVICE DATA & PROGRAM CD-ROM (#17041673)
* Confirm the service information.
2.
Computer equipped with CD-ROM drive and CompactFlash reader/
writer
3.
Memory card (CompactFlash, minimum 32 MB capacity)