What to do if Roland Controller V-1200HD cannot be controlled from the unit?
- LLynn CooperAug 10, 2025
If the Roland V-1200HD cannot be controlled from the unit, there might be an ID conflict if multiple V-1200HDR units or computers with V-1200HD RCS are connected. To resolve this, set a unique ID value on each device via the ROOT MENU > PROCESSOR > CONTROL SURFACE SETUP > “ID”. Also, ensure the LINK indicator on the top panel is lit. If it's dark, correctly connect the unit and the V-1200HD.