98
MIDI Implementation
PROGRAM CHANGE
This is used to switch image clip to be played or to select video input channel. (MIDI ch. = 1
fixed)In the V-LINK activated mode and while AUTOMIX is playing, this is transmitted
when the current time coincides with the pre-registered time for switching image clip.
Status
Second
C0H ppH
pp = Program No. : 00H - 7FH (1 - 128)
CHANNEL MODE MESSAGES
RESET ALL CONTROLLERS (Controller number 121)
This is transmitted when [CLEAR]+[V-LINK] are pressed. (MIDI ch.=1 fixed)
Status
Second Third
B0H 79H 00H
ALL NOTEOFF(Controller number 123)
This is transmitted when VS-2000 stops. (MIDI ch.=1 fixed)
Status
Second Third
B0H 7BH 00H
SYSTEM EXCLUSIVE MESSAGES
V-LINK ON
Status
Data Byte Status
F0H 41H,7FH,00H,51H,12H,10H, F7H
00H,00H,01H,aaH, ..., ffH,Sum
Byte Description
F0H Status of System Exclusive Message
41H Manufacturer ID (Roland)
7FH Device ID
00H 51H Model ID (DV-7PR)
12H Command ID (DT1)
10H Address MSB
00H Address
00H Address LSB
01H V-LINK ON/OFF (ON)
aaH Clip Ctrl Rx MIDI ch (*1)
bbH Color Ctrl Rx MIDI ch (*1)
ccH Note Message Enabled (*2)
ddH Fast Control Enabled (*3)
eeH MMC Control Mode (*4)
ffH MTC Control Mode(*5)
Sum Check Sum
F7H EOX (End of System Exclusive message)
These messages are transmitted when V-LINK function turns to enable.
VS-2000 doesn’t receive these messages.
(*1) 00H(ch.1) fixed
(*2) 00H(OFF) fixed
(*3) 01H(ON) fixed
(*4) It depends on MMC mode(OFF, MASTER or SLAVE) of VS-2000 as followings.
OFF 00H(OFF)
MASTER 01H(SLAVE)
SLAVE 02H(MASTER)
(*5) It depends on SYNC mode(INT or EXT) of VS-2000 as followings.
INT 01H(SLAVE)
EXT 02H(MASTER)
V-LINK OFF
Status
Data Byte Status
F0H 41H,7FH,00H,51H,12H,10H, F7H
00H,00H,00H,Sum
Byte Description
F0H Status of System Exclusive Message
41H Manufacturer ID (Roland)
7FH Device ID
00H 51H Model ID (DV-7PR)
12H Command ID (DT1)
10H Address MSB
00H Address
00H Address LSB
00H V-LINK ON/OFF (OFF)
Sum Check Sum
F7H EOX (End of System Exclusive message)
These messages are transmitted when V-LINK function turns to disable.
VS-2000 doesn’t receive these messages.
SET CLIP CONTROL ASSIGNMENT
Status
Data Byte Status
F0H 41H,7FH,00H,51H,12H,10H,10H,00H, F7H
05H,00H,00H,05H,0FH,0FH,00H,0BH,Sum
Byte Description
F0H Status of System Exclusive Message
41H Manufacturer ID (Roland)
7FH Device ID
00H 51H Model ID (DV-7PR)
12H Command ID (DT1)
10H Address MSB
10H Address
00H Address LSB
04H Playback Speed Control Assign(MSN)
08H Playback Speed Control Assign(LSN)
00H Dissolve Time Control Assign(MSN)
05H Dissolve Time Control Assign(LSN)
0FH Audio Level Control Assign (MSN) (*1)
0FH Audio Level Control Assign (LSN) (*1)
00H T Bar Control Assign (MSN)
0BH T Bar Control Assign (LSN)
Sum Check Sum
F7H EOX (End of System Exclusive message)
These messages are transmitted when V-LINK function turns to enable.
VS-2000 doesn’t receive these messages.
(*1) On the VS-2000, the audio level cannot be controlled.
SET COLOR CONTROL ASSIGNMENT
Status
Data Byte Status
F0H 41H,7FH,00H,51H,12H,10H,20H, F7H
00H,00H,07H,00H,0AH,00H,01H,Sum
Byte Description
F0H Status of System Exclusive Message
41H Manufacturer ID (Roland)
7FH Device ID
00H 51H Model IDModel ID (DV-7PR)
12H Command ID (DT1)
10H Address MSB
20H Address
00H Address LSB
00H Color Cb Control Assign(MSN)
07H Color Cb Control Assign(LSN)
00H Color Cr Control Assign(MSN)
0AH Color Cr Control Assign(LSN)
00H Brightness Control Assign(MSN)
01H Brightness Control Assign(LSN)
Sum Check Sum
F7H EOX (End of System Exclusive message)
These messages are transmitted when V-LINK function turns to enable.
VS-2000 doesn’t receive these messages.