18
RootsScrub B45 Series
Ÿ Prior to cleaning, sweep the floor before using the
machine.
Ÿ Use the machine in an even surface.
Ÿ Use only Non foaming chemical for cleaning.
Ÿ Always check the condition of Battery.
Ÿ Inspect the condition of float for any deposit of dirt.
Ÿ Dirty water to be drained if it reaches the cut-off stage.
Ÿ After usage, fresh & dirty water has to be drained.
Ÿ After usage of machine, squeegee lips, float assembly
and dirty water tank to be cleaned with fresh water.
Ÿ Don’t use inflammable liquids (thinner / kerosene) in
fresh water tank for cleaning operation.
Ÿ After usage during cleaning the machine don’t allow
water on the panel board.
Ÿ Don’t clean the machine with high water pressure jet
equipments.
Do’s
Do’s & Don’t’s
Don’ts
MAINTENANCE - Troubleshooting
Problem Cause Remedy
No power - nothing works Faulty power switch Contact service
Battery need to be recharged Recharge battery
Faulty battery Replace battery
Loose battery cable Tighten loose cable
Main fuse blown Replace the fuse
Main fuse blown Replace the fuse
Faulty brush motor or loose cable Contact service
Suction turbine does not
work
Faulty suction turbine switch Replace switch
Suction turbine fuse blown Replace the fuse
Faulty suction turbine Contact service
Carbon brushes worn Contact service
Insufficient water flow Water tank low Refill fresh water
Flow lever turned to stop Turn lever more to open
Water line clogged
Remove and blow with
compressed air
Water valve clogged Remove and clean
Poor water recovery Dirty water tank is full Empty dirty water tank
Suction hose is clogged Remove debris
Squeegee is clogged Remove debris
Squeegee lip is worn Rotate or replace lips
Faulty vacuum hose Contact service
Drain hose leak Hook up drain hose and close
Suction turbine faulty Contact service
Battery charge low Recharge battery
Short run time Battery run down Charge battery twice
Battery still down Contact service
Battery low on water Refill with distilled water
Battery over cycled Contact service