31
RootsScrub E4550 ES
Belt Tension Adjustment:
Set belt tension to 80 ± 20 N
Set the tension using Gates Meter. Turn the Idler pulley to set belt
tension.
WARNING:
Do not clean the machine by means of vapor jet or
high pressure cleaning equipment.
NOTE:
Use only a soft cloth or a sponge.
Use only mild detergent.
WARNING:
Disconnect power cord.
MAINTENANCE
Electrical Maintenance
DANGER
DANGER
Electrical Shock
or Burn Hazard.
Turn off power suppling
this equipment before
working on it.
The electrical equipment is located at the control unit assembly
of the machine.
The electrical safety system consists of Fuse and a Circuit Breaker
which are located on the rear panel assembly of the control unit.
A variety of fuses are used to protect the electrical systems in case
of a failure.
To change the fuse: Remove the cap of the fuse holder by
unscrewing it with a screwdriver. Remove the blown fuse and
replace with a new one with the specified rating. Put the cap back
in its place.
Fuse:
Belt
Idler Pulley