REV. 02-Feb-14 Pg. 1/19
Roswell Marine Audio
Amplier Owners Manual
RMA 600.1 C920-0029
RMA 500.2 C920-0030
RMA 600.4 C920-0031
RMA 800.5 C920-0032
Question and Answer IconNeed help?

Do you have a question about the Roswell RMA 500.2 and is the answer not in the manual?

Summary

Installation Instructions

Location of the Amplifier

Specifies secure mounting to a solid surface in a dry area with sufficient airflow for optimal heat dissipation.

Supplying Enough Power

Ensures the amplifier receives adequate power from the boat's electrical system for full output and performance.

Installation Best Practices

Grounding and Cable Management

Proper grounding to battery and routing signal cables away from power wires are essential.

Amplifier Controls and Features

Level Adjustment

Adjusts input sensitivity to match head unit output for optimal sound quality and noise reduction.

Protection Indicator LED

A red LED indicates the amplifier has entered protection mode, signaling an issue.

Control Panel Access

Describes how to access the amplifier's control panel by removing screws.

Understanding Crossover Controls

High-Pass Filter (HPF)

Allows high frequencies to pass, reducing lower signals below the cutoff frequency.

Low-Pass Filter (LPF)

Allows low frequencies to pass, reducing higher signals above the cutoff frequency.

Bandpass Filter (BP)

Uses both HPF and LPF to play a selected range of frequencies, isolating specific bands.

Subsonic Filter Function

Reduces signals below the cutoff frequency to protect equipment and save battery power.

Amplifier Features and Outputs

Bass Boost Functionality

Adjustable feature to boost low frequencies, use with caution for powerful output.

Remote Gain Control Module

Module for easy remote gain adjustment without accessing the amplifier directly.

RCA Line Out Port

Provides full range mono signal for connecting multiple amplifiers.

Speaker Output Terminals

Block style terminals for speaker connections; ensure proper impedance and wiring.

Detailed Installation Steps

Power and Fuse Connections

Connect red 4 AWG wire from battery to amplifier with an in-line fuse within 12 inches.

Ground and Remote Wiring

Connect black ground wire to battery and blue remote wire from head unit.

Speaker and RCA Connections

Connect speaker wires to outputs and RCAs to inputs, verifying polarity and impedance.

RMA 600.1 Wiring Diagrams

Power Input Connections

Diagram showing +12V, GND, and REMOTE connections for the RMA 600.1 amplifier.

Amplifier Application Examples

Illustrates connection configurations for subwoofers with the RMA 600.1 amplifier.

RMA 500.2 Amplifier Setup

Control Panel Layout

Details the controls for the RMA 500.2 amplifier, including Bass EQ, LPF, and Level settings.

Power Input and Application Diagrams

Diagrams for power input and wiring configurations for 2-channel and bridged modes.

RMA 500.2 Configurations

2 CH and Bridged Mono Output Wiring

Illustrates speaker wiring for stereo and bridged configurations on the 500.2.

Control Panel Settings Details

Shows details of LPF and HPF controls on the RMA 500.2 amplifier for fine-tuning.

RMA 600.4 Wiring and Applications

Power Input Connections Diagram

Diagram for connecting power, ground, and remote for the RMA 600.4 amplifier.

4 CH and 3 CH Output Configurations

Illustrates speaker wiring for 4-channel and 3-channel bridged modes on the 600.4.

RMA 600.4 Modes and Controls

2 CH Mode Operation

Details the 'double' setting for tuning identical speakers in 2 or 4 speaker configurations.

Connection Diagrams for Outputs

Illustrates 4CH and 2CH speaker output configurations for the RMA 600.4.

Control Panel Settings Overview

Shows detailed settings for LPF and HPF controls on the RMA 600.4 amplifier.

RMA 800.5 Wiring and Applications

Power Input and RCA Connections

Diagram for power, ground, remote, and RCA inputs for the RMA 800.5 amplifier.

5 CH Mode Output Configurations

Illustrates 5-channel speaker output configurations and RCA input usage for the RMA 800.5.

RMA 800.5 Configurations

3 CH Bridged Output Diagram

Wiring diagram for a 3-channel bridged output configuration on the RMA 800.5.

4 CH and 2 CH Mode Wiring

Illustrates 4-channel and 2-channel wiring setups for the RMA 800.5 amplifier.

RMA 800.5 Control Panel Details

2 CH Bridged Output Wiring Diagram

Diagram showing speaker connections for 2-channel bridged mode on the RMA 800.5.

Control Panel Settings Overview

Details the various controls including HPF, LPF, Bass EQ, and Subsonic on the RMA 800.5.

Technical Specifications

RMA 600.1 Specifications

Details power output, frequency response, bass EQ, sensitivity, and S/N ratio for the 600.1 model.

RMA 500.2 Specifications

Details power output, frequency response, bass EQ, sensitivity, and S/N ratio for the 500.2 model.

RMA 600.4 Specifications

Details power output, frequency response, bass EQ, sensitivity, and S/N ratio for the 600.4 model.

RMA 800.5 Specifications

Details power output, frequency response, bass EQ, sensitivity, and S/N ratio for the 800.5 model.

Important Safety Information

Amplifier Heat Management

Amplifiers can get hot; ensure proper airflow and avoid obstructions for optimal cooling.

Proximity Warnings

Keep items like life vests, towels, or coolers away from direct contact with the amplifier.

Hearing Protection Advisory

Continuous exposure to high sound pressure levels can cause permanent hearing loss.

Warranty and Service Guidelines

Limited Warranty Policy

One-year warranty against defects in material and workmanship for original purchasers.

Warranty Exclusions and Limitations

Excludes damage from accident, misuse, improper wiring, or tampering; limits liability.

Warranty Claim Procedure

Contact warranty department, obtain RA#, and return product freight prepaid with proof of purchase.

Roswell RMA 500.2 Specifications

General IconGeneral
Channels2
RMS Power @ 4 Ohms125W x 2
RMS Power @ 2 Ohms250W x 2
RMS Power @ 4 Ohms Bridged500W x 1
THD @ 4 Ohms<0.05%
S/N Ratio>90dB
Damping Factor>200
Input Sensitivity200mV - 6V
Bass Boost0dB - 12dB
Fuse Rating2 x 40A