4 x Faults and malfunctions
FA ROTEX RoCon HP - 03/2013
33
Tab. 4-2 Error codes on the main control unit of HPSU compact
9040 U3 Screed function Screed function active No fault.
9041 U4
Transmission error
Communication fault
Malfunction message. Contact ROTEX heating technician.
9042 U5 Communication fault
9043 U7 Communication fault
9044 UA Communication fault
E75
Outside temperature sen-
sor
Outside temperature sensor defective.
E76
Domestic hot water tem-
perature sensor
Domestic hot water temperature sensor defective.
E81 Circuit board RoCon BM1 Parameter store in EEPROM faulty.
E88 Circuit board RoCon BM1 Parameter store in external flash memory faulty.
E91 Connected CAN modules Bus detection of a CAN module doubly present.
E128 Temperature sensor Temperature sensor in flow sensor defective.
E129 Pressure sensor Pressure sensor defective.
E8005
Water pressure heating
network too low
Water pressure has fallen below the permissible minimum value.
W8006 Heating network Maximum permissible pressure drop exceeded.
W8007
Water pressure heating
network too high
Water pressure has exceeded the permissible maximum value.
Code Error message Component/Designation Fault and possible causes
Display Internal
Respect the maximum tightening torque of 10 Nm for:
T
V1
, T
V2
, T
V, BH1
, T
V, BH2
, T
R2
.

Other manuals for Rotex HPSU compact (V5)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotex HPSU compact (V5) and is the answer not in the manual?

Rotex HPSU compact (V5) Specifications

General IconGeneral
BrandRotex
ModelHPSU compact (V5)
CategoryHeat Pump
LanguageEnglish

Related product manuals