EasyManua.ls Logo

Rotex RKHBRD011ABV1 User Manual

Rotex RKHBRD011ABV1
440 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
INSTALLATIONSANLEITUNG
Installationsanleitung
Inneneinheit für Luft-Wasser-Wärmepumpensystem
Deutsch
Installation manual
Indoor unit for air to water heat pump system
English
Manuale d'installazione
Unità interna per sistema a pompe di calore aria-acqua
Italiano
Manuel d'installation
Unité intérieure pour système de pompe à chaleur air à eau
Français
Montagehandleiding
Binnenunit voor lucht-water-warmtepompsysteem
Nederlands
Manual de instalación
Unidad interior para bomba de calor de aire-agua
Español
Manual de instalação
Unidade interior para o sistema de bomba de calor ar/água
Portugues
Montaj kılavuzu
Hava su tipi ısı pompa sistemi iç ünitesi
Türkçe
Manual de instalare
Unitate interioară pentru sistem de pompă termică aer la apă
română
Instalační manuál
Vnitřní jednotka pro systém tepelných čerpadel vzduch-voda
čeština
RKHBRD011ABV1
RKHBRD014ABV1
RKHBRD016ABV1
RKHBRD011ABY1
RKHBRD014ABY1
RKHBRD016ABY1
Inneneinheit für
Luft-Wasser-Wärmepumpensystem

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Rotex RKHBRD011ABV1 and is the answer not in the manual?

Rotex RKHBRD011ABV1 Specifications

General IconGeneral
BrandRotex
ModelRKHBRD011ABV1
CategoryHeat Pump
LanguageEnglish

Summary

General Information

Scope of this Manual

Describes the procedures covered in this installation manual for RKHBRD indoor units.

Model Identification

Explains the coding system used for identifying RKHBRD indoor unit models.

Typical Application Examples

Illustrates common system configurations and applications for the indoor unit.

Application Examples with Only 1 Heat Emitter and 1 Heat Source

Details system setups with a single heat emitter and one heat source.

Application Examples with 2 or More Different Heat Emitters and 1 Heat Source

Covers installations using multiple heat emitters with a single heat source.

Application Examples with 2 Different Heat Sources

Discusses system configurations involving an auxiliary boiler and the RKHBRD indoor unit.

Design of the Hydraulic System

Provides guidelines for designing the hydraulic system, considering external static pressure.

Accessories

Lists accessories supplied with the indoor unit and describes main components.

Overview of the Indoor Unit

Main components

Identifies and describes the key physical components of the indoor unit.

Switch box main components

Details the components located within the switch box of the indoor unit.

Functional diagram

Presents a schematic diagram illustrating the functional flow of the indoor unit.

Installation of the Indoor Unit

Selecting an installation location

Provides guidance on choosing a suitable indoor location, considering space and environmental factors.

Dimensions and service space

Specifies the physical dimensions of the unit and required clearance for servicing.

Inspecting and handling the unit

Outlines procedures for checking and handling the unit upon delivery and during installation.

Installing the indoor unit

Details the steps for physically placing and securing the indoor unit in its final location.

Piping Connection Work

Refrigerant Piping Work

Guidelines for connecting refrigerant pipes between indoor and outdoor units.

Water Piping Work

Details water circuit connections and initial checks.

Water Volume and Expansion Vessel Checks

Covers checking water volume and setting expansion vessel pre-pressure.

Water Circuit Charging and Precautions

Explains water circuit charging, field piping precautions, and insulation.

Electrical Wiring Work

Precautions on electrical wiring work

Highlights safety warnings and essential precautions for electrical wiring.

Internal wiring - Parts table

Lists and defines the abbreviations for internal wiring components.

System overview of field wiring

Provides a general overview of field wiring connections to terminal blocks.

Connection of the indoor unit power supply and communication cable(s)

Details the process of connecting power and communication cables to the unit.

Installation of the Remote Controller

Remote controller mounting

Step-by-step instructions for mounting the remote controller unit.

Connecting the remote controller

Details the wiring process for connecting the remote controller to the indoor unit.

Benefit kWh Rate Power Supply Connection

Connection types and requirements

Explains how to connect the unit to different types of benefit kWh rate power supplies.

Possible types of benefit kWh rate power supply

Illustrates various connection diagrams for benefit kWh rate power supply types.

Start-Up and Configuration

Pre-operation checks

Lists essential checks to perform before powering up the unit.

Field settings

Explains the process of configuring unit parameters based on installation and user needs.

Field Settings: Remote Control and Schedules

Remote Control Setup and Timer Modes

Configures user permissions, temperature compensation, and schedule timer modes.

Field Settings: DHW, Setback, and Weather Dependence

Domestic Hot Water Heating Settings

Manages automatic storage, reheat, and disinfection for domestic hot water.

Automatic Setback Function

Manages automatic reduction of room temperature during specific periods.

Weather Dependent Set Point

Adjusts leaving water temperature based on outdoor ambient conditions.

Field Settings: Options and Disinfection

Option Setup and Disinfection Function

Configures options like DHW tank, thermostats, backup heater, kWh rate, and disinfection.

Field Settings: Advanced Options and Compensation

Option Setup (Part 2)

Configures bottom plate heater, multiple set points, and remote controller settings.

Automatic Temperature Compensation

Allows adjustment of temperature sensor readings for accuracy.

Field Settings: DHW Limits and Service Modes

Domestic Hot Water Set Points and Limits

Sets parameters for reheat, storage, and leaving water temperature limits.

Heating Retention Times and Service Modes

Sets operation times for DHW and configures service modes like vacuum and pump operation.

Simultaneous Demand of Space Heating and Domestic Water Heating

Demand Management with Remote Controller

Details how the remote controller manages simultaneous space and domestic water heating demands.

External Room Thermostat Control

Explains how an external room thermostat influences simultaneous heating operations.

Multiple Set Point Control Patterns

Describes configurations for using multiple temperature set points for different heating zones.

Maintenance and Service

Maintenance Activities and Checks

Outlines regular checks and inspections required for optimal unit performance.

Troubleshooting and General Guidelines

Provides guidance for diagnosing and resolving common unit issues and general safety advice.

Final Check and Test Run

Pre-Operation Checks and Pump Operation

Performs final checks, pump operation for air purging, and initial unit startup.

Test Run Procedures

Guides through testing space heating and domestic water heating functionalities.

Unit Specifications

Technical Specifications

Provides detailed technical data for different unit models, including capacity and dimensions.

Electrical Specifications

Lists electrical parameters such as phase, voltage, current, and fuse recommendations.

Annex: System Configuration Flowcharts

Space Heating Start-Up Guide

Provides a flowchart for setting up space heating based on appliance type and control methods.

Domestic Water Heating Configuration

Presents flowcharts for configuring domestic water heating modes and operations.

Simultaneous Demand Flowchart

Illustrates the logic for managing simultaneous space heating and domestic water heating requests.

Related product manuals