Change the ROWASHER Microbe Filter Mat EVERY MONTH
To Maintain Cleaning Performance
For Technical Support or to order more consumables
Tel: +44 (0)121 526 8181 www.rozone.co.uk
7. OPERATION
Cleaning is a manual operation using the flo-thru brush in the ROwasher sink top
Wear appropriate PPE such as safety goggles and protective gloves
Place the dirty parts in the sink tray (maximum weight 150kg must not be exceeded)
Press the green button to turn the pump on. Wet the sink, nozzle and brushes prior
to cleaning to prevent grease and dirt sticking to the surfaces. The pump will run for
5 minutes and then automatically switch off.
Open the tap of the desired tool – you can use both the nozzle and the flo-thru brush
at the same time for maximum cleaning if desired.
Note: Any parts susceptible to corrosion should not be left in sink after cleaning
As with all partswashers excess grease and oil should be disposed of prior to
washing. DO NOT USE THE ROWASHER AS A WASTE DUMP
Do not turn the ROwasher off unless it is for safety reasons, moving or servicing. The
optimum temperature for the activity of the microbes and therefore breakdown of
oil and grease is between 37°c and 42°c, therefore the ROwasher must always be left
switched on.
8. ENERGY SAVING MODE
After a 4 hour period of inactivity the ROwasher automatically switches to energy
saving mode (37°c) and remains at this temperature until the pump is restarted
when it will return to 42°c