MODEL 51240B/53540B/53640B/61240B/63540B/63640B
21
6. Working process: Service→ Backwash→ Brine Draw Slow Rinse→
Fast Rinse→ Brine Refill →Service
C. Usage
After being accomplished installation, parameter setting and trail
running, the valve could be put into use. In order to ensure the quality of
outlet water can reach the requirement, the user should complete the
below works:
Ensure that there is solid salt all the time in the brine tank in the course
of using when this valve is used for softening. The brine tank should be
added the clean water softening salts only, at least 99.5% pure, forbidding
use the fine salt and iodized salt.
Test the outlet water and raw water hardness at regular time. When the
outlet water hardness is unqualified, please press the and the valve
will temporary regenerate again( It will not affect the original set operation
cycle)
When the feed water hardness changed a lot, you can adjust the water
treatment capacity as follow:
Press and hold both and for 5 seconds to lift the lock status.
Press , and the lights on, then press , the digital area will show
control mode A-01 or A-02. Press three times to the digital area, it will
show the given water treatment capacity. Press again, the water
treatment capacity value flash, then press or to reset the value to be
requested. Press twice and hear a sound “Di”, then finish the
adjustment. Press exit and turn back the service status.
For A-01 control mode (Delayed regeneration type), please pay
attention to whether the time is current or not. If the time is not right, you
can adjust as follow: After lifting the lock status, press , the and
light on. Then press , the and hour value flash. Press or
continuously, reset the hour value; Press again, and minute value
flash. Press or continuously, reset the minute value; Press and
hear a sound “Di”, then finish the adjustment. Press exit and turn back
the service status.