Why is the capacity of my Runxin 63504 decreasing?
- CCassie FrySep 12, 2025
If the capacity of your Runxin Control Unit is decreasing, it could be because the unit fails to regenerate or doesn't regenerate properly; regenerate according to the correct operation requirements. A fouled resin bed can also cause this; increase the backwash flow rate and time, and clean or change the resin. Check if the salt setting is not proper and readjust the brine drawing time. If the softener setting is not proper, recount and reset according to the test of outlet water. Raw water quality deterioration can also lead to decreased capacity; regenerate the unit manually temporarily, then reset the regeneration cycle. Finally, a stuck turbine of the flow meter can be the cause; disassemble the flow meter and clean or replace the turbine.