EasyManua.ls Logo

Runxin 63604 - User Manual

Default Icon
63 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Multi-functional Flow Control Valve for
Water Treatment Systems
63504,63504B (Old Model No.: F63C1,F63G1)
63604,63604B (Old Model No.: F63C3,F63G3)
73504,73504B (Old Model No.: F68C1,F68G1)
73604,73604B (Old Model No.: F68C3,F68G3)
User Manual
Please read this manual in details before using the valve
and keep it properly in order to consult in the future.
0WRX.466.501
International Patent Public No.:
WO 2006/007772
China Patent No.: ZL02220153.X,
ZL200420078956.5
US Patent No.: 7549446
India Patent No.: 232582
Russia Patent No.:2349819
South Korea Patent No.:10-0914137
Mexico Patent No.: 268581
Australia Patent No.: 2005263257
Philippine Patent No.: 1-2006-502553
Taiwan Patent No.:M287896

Table of Contents

Questions and Answers

  • W
    William CainSep 12, 2025
    Why do all indicators display on the front panel of my Runxin 63604 Control Unit?
    • K
      Kevin BensonSep 12, 2025
      If all indicators are displaying on the front panel of your Runxin Control Unit, it could be due to the wiring of the front panel with the controller failing to work; check and replace the wiring. If the control board is faulty, replace it. A damaged transformer can also cause this; check and replace the transformer. Finally, unstable electrical service can be the cause; check and adjust the electrical service.
  • T
    Taylor BrownAug 25, 2025
    Why my Runxin 63604 Control Unit uses too much salt?
    • P
      Peter ShortAug 25, 2025
      If your Runxin Control Unit is using too much salt, start by checking the salt usage and salt setting to ensure they are properly configured. If there's excessive water in the brine tank, refer to problem no. 6 for troubleshooting steps.
  • P
    Patricia CurryAug 26, 2025
    What to do if Runxin 63604 Control Unit softener fails to draw brine?
    • T
      Timothy PattersonAug 27, 2025
      If your Runxin Control Unit softener isn't drawing brine, it could be due to several reasons. First, ensure that the line pressure is adequate; increase it if it's too low. Check for any blockages in the brine line and clean it if necessary. Inspect the brine line for leaks and replace it if needed. Also, the injector might be plugged, so clean or replace it. An internal control leak could also be the cause, requiring replacement of the valve body. Additionally, check if the drain line is plugged and clean the drain line flow control. Finally, ensure that the sizes of the injector and DLFC match the tank requirements according to the P20 requirements.
  • B
    Benjamin HowardAug 27, 2025
    Why is there excessive water in the brine tank of my Runxin Control Unit?
    • T
      tonychambersAug 27, 2025
      If there's excessive water in the brine tank of your Runxin Control Unit, it could be due to several reasons. The refilling time might be too long, so reset it to the correct duration. Check the brine line for any foreign material and clean it. Also, inspect the brine valve for foreign material and clean both the valve and the brine line. If a safety brine valve isn't installed and there's a power failure during salting, stop the water supply and restart, or install a safety brine valve in the salt tank. Lastly, the safety brine valve itself might be broken down, requiring repair or replacement.
  • D
    Destiny ChavezAug 29, 2025
    How to correct regeneration time on Runxin 63604 Control Unit?
    • J
      Jimmy AdamsAug 29, 2025
      If the regeneration time on your Runxin Control Unit is incorrect, check the program and reset the time of day accordingly. If there was a power failure lasting more than 3 days, no solution was mentioned.
  • B
    Brittany CarrAug 30, 2025
    Why is there pressure lost or iron in conditioned water with my Runxin 63604?
    • R
      richard80Aug 31, 2025
      If you're experiencing pressure loss or iron in the conditioned water from your Runxin Control Unit, start by cleaning the water supply pipe if there's iron present. If there's an iron mass in the softener, clean the valve, add resin cleaning chemical, and increase the frequency of regeneration. For a fouled resin bed, check the backwash, brine draw, and brine tank refill, and increase the frequency of regeneration and backwash time. If there's too much iron in the raw water, iron removal equipment is required to install before softening.
  • D
    David HuntSep 18, 2025
    What does E3 or E4 Flash mean on Runxin 63604 Control Unit?
    • B
      Brandy EvansSep 18, 2025
      If 'E3' or 'E4' is flashing on your Runxin Control Unit, it indicates that the control board is faulty and needs to be replaced.
  • V
    vchapmanNov 20, 2025
    Why is my Runxin 63604 Control Unit softener supplying hard water?
    • R
      Ryan SimmonsNov 20, 2025
      If your Runxin Control Unit softener is supplying hard water, several factors could be the cause. Check if the bypass valve is open or leaking and close or repair it. Ensure there is enough salt in the brine tank, maintaining the salt level above the water level. Inspect the injector for any blockages and clean or replace it if necessary. Also, verify that sufficient water is flowing into the brine tank by checking the brine tank refill time. Inspect the O-ring on the riser pipe for leaks and ensure the riser pipe isn't cracked, and check the tube pilot. If there's an internal valve leak, consider changing the valve body. Confirm that the regeneration cycles are correctly set in the program. Check for resin shortage and add resin to the mineral tank, looking for any resin leaks. Finally, b...
  • T
    taylorfrederickSep 9, 2025
    Why is there salt water in the softened water from my Runxin Control Unit?
    • M
      Mark NelsonSep 9, 2025
      If you notice salt water in the softened water from your Runxin Control Unit, it could be due to foreign material in the injector or injector malfunction; clean and repair the injector. If the brine valve cannot be shut off, repair and clean it. Also, the rapid rinse time might be too short, so extend it.
  • K
    Kristin JonesSep 6, 2025
    Why is the brine interrupted or irregular in my Runxin 63604 Control Unit?
    • M
      Michelle CameronSep 6, 2025
      If you're experiencing interrupted or irregular brine in your Runxin Control Unit, it could be due to several reasons. Ensure that the water pressure is adequate and stable; increase it if it's too low. Check the injector for any blockages or faults and clean or replace it if necessary. Look for air in the resin tank and find the reason. Also, check for floccules in the resin tank during backwash and clean them.

Summary

Product Overview

1.1. Main Application & Applicability

Details the primary uses and suitability for various water treatment systems.

1.2. Product Characteristics

Highlights key features like simple structure, manual function, and display types.

Service Condition

Service Condition Details

Specifies the required working conditions, environment, and inlet water quality.

Product Structure and Technical Parameters

Product Dimensions and Parameters

Provides product dimensions and technical specifications for accurate understanding.

Installation

Installation Notice and Device Location

Guides on preliminary information, tools, and optimal placement for the unit.

Pipeline Installation

Details the process for connecting inlet, outlet, drain, and brine lines.

Basic Setting & Usage

2.1. The Function of PC Board

Explains the indicators and buttons on the control board for user interaction.

2.2. Parameter Specifications

Details parameter specifications and factory defaults for system configuration.

Applications

3.1. Softener Flow Chart

Visually represents the operational flow through different stages of the softener.

3.2. The Function and Connection of PC Board

Describes the main functions and connection ports on the control board.

3.3. System Configuration and Flow Rate Curve

Outlines system setup options and characteristic flow rate performance.

3.4. Parameter Settlement

Guides on calculating and setting operational parameters like service time and backwash.

3.5. Parameter Enquiry and Setting

Describes how to view current settings and adjust parameters for optimal performance.

3.6. Trial Running

Provides a step-by-step guide for testing the valve after installation and setup.

3.7. Trouble-Shooting

Lists common problems, their causes, and recommended solutions for valve faults.

3.8. Assembly & Parts

Details the components of the flow meter, animated connector, and valve body assemblies.

Warranty Card

Warranty Information

Contains information about product warranty, terms, and service registration.