Multi-functional Flow Control Valve for
Water Treatment Systems
63504,63504B (Old Model No.: F63C1,F63G1)
63604,63604B (Old Model No.: F63C3,F63G3)
73504,73504B (Old Model No.: F68C1,F68G1)
73604,73604B (Old Model No.: F68C3,F68G3)
User Manual
Please read this manual in details before using the valve
and keep it properly in order to consult in the future.
0WRX.466.501
International Patent Public No.:
WO 2006/007772
China Patent No.: ZL02220153.X,
ZL200420078956.5
US Patent No.: 7549446
India Patent No.: 232582
Russia Patent No.:2349819
South Korea Patent No.:10-0914137
Mexico Patent No.: 268581
Australia Patent No.: 2005263257
Philippine Patent No.: 1-2006-502553
Taiwan Patent No.:M287896

Table of Contents

Questions and Answers

  • T
    Tyler TuckerSep 12, 2025
    Why is the capacity of my Runxin Control Unit decreasing?
    • R
      rachel49Sep 12, 2025
      If the capacity of your Runxin Control Unit is decreasing, it could be because the unit fails to regenerate or doesn't regenerate properly; regenerate according to the correct operation requirements. A fouled resin bed can also cause this; increase the backwash flow rate and time, and clean or change the resin. Check if the salt setting is not proper and readjust the brine drawing time. If the softener setting is not proper, recount and reset according to the test of outlet water. Raw water quality deterioration can also lead to decreased capacity; regenerate the unit manually temporarily, then reset the regeneration cycle. Finally, a stuck turbine of the flow meter can be the cause; disassemble the flow meter and clean or replace the turbine.
  • M
    Michelle TrevinoAug 25, 2025
    Why my Runxin Control Unit uses too much salt?
    • R
      reynoldsmargaretAug 25, 2025
      If your Runxin Control Unit is using too much salt, start by checking the salt usage and salt setting to ensure they are properly configured. If there's excessive water in the brine tank, refer to problem no. 6 for troubleshooting steps.
  • E
    ejonesAug 27, 2025
    What to do if Runxin F63C3 Control Unit softener fails to draw brine?
    • A
      annette60Aug 27, 2025
      If your Runxin Control Unit softener isn't drawing brine, it could be due to several reasons. First, ensure that the line pressure is adequate; increase it if it's too low. Check for any blockages in the brine line and clean it if necessary. Inspect the brine line for leaks and replace it if needed. Also, the injector might be plugged, so clean or replace it. An internal control leak could also be the cause, requiring replacement of the valve body. Additionally, check if the drain line is plugged and clean the drain line flow control. Finally, ensure that the sizes of the injector and DLFC match the tank requirements according to the P20 requirements.
  • K
    Katherine MorrisAug 27, 2025
    Why is there excessive water in the brine tank of my Runxin F63C3?
    • B
      bradley69Aug 28, 2025
      If there's excessive water in the brine tank of your Runxin Control Unit, it could be due to several reasons. The refilling time might be too long, so reset it to the correct duration. Check the brine line for any foreign material and clean it. Also, inspect the brine valve for foreign material and clean both the valve and the brine line. If a safety brine valve isn't installed and there's a power failure during salting, stop the water supply and restart, or install a safety brine valve in the salt tank. Lastly, the safety brine valve itself might be broken down, requiring repair or replacement.
  • C
    Charles MeyerAug 29, 2025
    How to correct regeneration time on Runxin Control Unit?
    • H
      hhansonAug 29, 2025
      If the regeneration time on your Runxin Control Unit is incorrect, check the program and reset the time of day accordingly. If there was a power failure lasting more than 3 days, no solution was mentioned.
  • M
    Michael CarterAug 31, 2025
    Why is there pressure lost or iron in conditioned water with my Runxin F63C3 Control Unit?
    • H
      Heather CastroAug 31, 2025
      If you're experiencing pressure loss or iron in the conditioned water from your Runxin Control Unit, start by cleaning the water supply pipe if there's iron present. If there's an iron mass in the softener, clean the valve, add resin cleaning chemical, and increase the frequency of regeneration. For a fouled resin bed, check the backwash, brine draw, and brine tank refill, and increase the frequency of regeneration and backwash time. If there's too much iron in the raw water, iron removal equipment is required to install before softening.
  • K
    kjensenSep 18, 2025
    What does E3 or E4 Flash mean on Runxin F63C3 Control Unit?
    • U
      ujohnsonSep 18, 2025
      If 'E3' or 'E4' is flashing on your Runxin Control Unit, it indicates that the control board is faulty and needs to be replaced.
  • K
    Kelly NguyenNov 20, 2025
    Why is my Runxin F63C3 Control Unit softener supplying hard water?
    • R
      Robert MorseNov 20, 2025
      If your Runxin Control Unit softener is supplying hard water, several factors could be the cause. Check if the bypass valve is open or leaking and close or repair it. Ensure there is enough salt in the brine tank, maintaining the salt level above the water level. Inspect the injector for any blockages and clean or replace it if necessary. Also, verify that sufficient water is flowing into the brine tank by checking the brine tank refill time. Inspect the O-ring on the riser pipe for leaks and ensure the riser pipe isn't cracked, and check the tube pilot. If there's an internal valve leak, consider changing the valve body. Confirm that the regeneration cycles are correctly set in the program. Check for resin shortage and add resin to the mineral tank, looking for any resin leaks. Finally, b...
  • L
    lisa27Sep 9, 2025
    Why is there salt water in the softened water from my Runxin F63C3 Control Unit?
    • D
      dannygrantSep 9, 2025
      If you notice salt water in the softened water from your Runxin Control Unit, it could be due to foreign material in the injector or injector malfunction; clean and repair the injector. If the brine valve cannot be shut off, repair and clean it. Also, the rapid rinse time might be too short, so extend it.
  • A
    Andrew MillerSep 6, 2025
    Why is the brine interrupted or irregular in my Runxin Control Unit?
    • L
      Leah BryanSep 6, 2025
      If you're experiencing interrupted or irregular brine in your Runxin Control Unit, it could be due to several reasons. Ensure that the water pressure is adequate and stable; increase it if it's too low. Check the injector for any blockages or faults and clean or replace it if necessary. Look for air in the resin tank and find the reason. Also, check for floccules in the resin tank during backwash and clean them.

Summary

Product Overview

Installation

Provides instructions and guidance for installing the valve.

Basic Setting & Usage

Basic Setting & Usage

Details the parameter settings and basic operational steps.

Applications

Parameter settlement

Explains how to calculate and set operational parameters.

Trial running

Trouble-Shooting

Control Valve Fault

Lists common control valve issues and their resolutions.

Controller Fault

Addresses problems related to the electronic controller unit.

Assembly & Parts

Runxin F63C3 Specifications

General IconGeneral
BrandRunxin
ModelF63C3
CategoryControl Unit
LanguageEnglish

Related product manuals