Multi-functional Flow Control Valve for
Water Treatment Systems
63504,63504B (Old Model No.: F63C1,F63G1)
63604,63604B (Old Model No.: F63C3,F63G3)
73504,73504B (Old Model No.: F68C1,F68G1)
73604,73604B (Old Model No.: F68C3,F68G3)
User Manual
Please read this manual in details before using the valve
and keep it properly in order to consult in the future.
0WRX.466.501
International Patent Public No.:
WO 2006/007772
China Patent No.: ZL02220153.X,
ZL200420078956.5
US Patent No.: 7549446
India Patent No.: 232582
Russia Patent No.:2349819
South Korea Patent No.:10-0914137
Mexico Patent No.: 268581
Australia Patent No.: 2005263257
Philippine Patent No.: 1-2006-502553
Taiwan Patent No.:M287896

Table of Contents

Questions and Answers

  • W
    wendygibsonAug 23, 2025
    How to fix a Runxin Control Unit that fails to regenerate?
    • N
      Nicole MillerAug 23, 2025
      If your Runxin Control Unit softener fails to regenerate, there might be several reasons: * Check the electrical service to the unit. Make sure it has permanent electrical service by checking the fuse, plug, pull chain, or switch. * Verify that the regeneration cycles are set correctly and reset them if necessary. * The controller or the motor could be defective and need replacement.
  • C
    Carolyn HansonSep 4, 2025
    What to do if Runxin F63C3 Control Unit drain flows continuously?
    • G
      Gregory HernandezSep 4, 2025
      If the drain flows continuously in your Runxin Control Unit, check and repair the valve body or replace it if there's an internal valve leak. When electricity fails, and the valve stops in the backwash or fast rinse position, adjust the valve to the service position or turn off the bypass valve and restart when electricity is supplied.
  • C
    Cynthia TurnerSep 3, 2025
    Why does my Runxin F63C3 control cycle continuously?
    • K
      Kim WebsterSep 3, 2025
      If your Runxin Control Unit control cycle runs continuously, check and connect the locating signal wiring if there's a breakdown. If the controller is faulty, replace it. Remove any foreign material stuck in the driving gear. Also, check the program settings and reset them if the time of regeneration steps were set to zero.
  • M
    Maria YangSep 1, 2025
    What causes mineral loss through the drain line in Runxin F63C3?
    • R
      Ronald PerezSep 1, 2025
      If you notice mineral loss through the drain line of your Runxin Control Unit, first ensure that your well system has a proper air eliminator control if air is present in the water system. If the bottom strainer is broken, replace it with a new one. Also, check for the proper drain rate if the drain line control is improperly sized.
  • M
    Michael CarterAug 31, 2025
    Why is there pressure lost or iron in conditioned water with my Runxin F63C3 Control Unit?
    • H
      Heather CastroAug 31, 2025
      If you're experiencing pressure loss or iron in the conditioned water from your Runxin Control Unit, start by cleaning the water supply pipe if there's iron present. If there's an iron mass in the softener, clean the valve, add resin cleaning chemical, and increase the frequency of regeneration. For a fouled resin bed, check the backwash, brine draw, and brine tank refill, and increase the frequency of regeneration and backwash time. If there's too much iron in the raw water, iron removal equipment is required to install before softening.
  • C
    Charles MeyerAug 29, 2025
    How to correct regeneration time on Runxin Control Unit?
    • H
      hhansonAug 29, 2025
      If the regeneration time on your Runxin Control Unit is incorrect, check the program and reset the time of day accordingly. If there was a power failure lasting more than 3 days, no solution was mentioned.
  • K
    Katherine MorrisAug 27, 2025
    Why is there excessive water in the brine tank of my Runxin F63C3?
    • B
      bradley69Aug 28, 2025
      If there's excessive water in the brine tank of your Runxin Control Unit, it could be due to several reasons. The refilling time might be too long, so reset it to the correct duration. Check the brine line for any foreign material and clean it. Also, inspect the brine valve for foreign material and clean both the valve and the brine line. If a safety brine valve isn't installed and there's a power failure during salting, stop the water supply and restart, or install a safety brine valve in the salt tank. Lastly, the safety brine valve itself might be broken down, requiring repair or replacement.
  • E
    ejonesAug 27, 2025
    What to do if Runxin F63C3 Control Unit softener fails to draw brine?
    • A
      annette60Aug 27, 2025
      If your Runxin Control Unit softener isn't drawing brine, it could be due to several reasons. First, ensure that the line pressure is adequate; increase it if it's too low. Check for any blockages in the brine line and clean it if necessary. Inspect the brine line for leaks and replace it if needed. Also, the injector might be plugged, so clean or replace it. An internal control leak could also be the cause, requiring replacement of the valve body. Additionally, check if the drain line is plugged and clean the drain line flow control. Finally, ensure that the sizes of the injector and DLFC match the tank requirements according to the P20 requirements.
  • M
    Michelle TrevinoAug 25, 2025
    Why my Runxin Control Unit uses too much salt?
    • R
      reynoldsmargaretAug 25, 2025
      If your Runxin Control Unit is using too much salt, start by checking the salt usage and salt setting to ensure they are properly configured. If there's excessive water in the brine tank, refer to problem no. 6 for troubleshooting steps.

Summary

Product Overview

Installation

Provides instructions and guidance for installing the valve.

Basic Setting & Usage

Basic Setting & Usage

Details the parameter settings and basic operational steps.

Applications

Parameter settlement

Explains how to calculate and set operational parameters.

Trial running

Trouble-Shooting

Control Valve Fault

Lists common control valve issues and their resolutions.

Controller Fault

Addresses problems related to the electronic controller unit.

Assembly & Parts

Runxin F63C3 Specifications

General IconGeneral
BrandRunxin
ModelF63C3
CategoryControl Unit
LanguageEnglish

Related product manuals