MODEL 63504-F63C1/63604-F63C3/73504-F68C1/73604-F68C3
47
brine line are connected.
13.Salt water
in soften water.
A. Foreign material in
injector pr injector fails to
work.
B. Brine valve cannot be
shut-off.
C. Time of rapid rinse too
short.
A. Clean and repair injector.
B. Repair brine valve and clean it.
C. Extend rapid rinse time.
14.Unit
capacity
decreases.
A. Unit fails to regenerate
or regenerate not properly.
B. Fouled resin bed.
C. Salt setting not proper.
D. Softener setting not
proper.
E. Raw water quality
deterioration.
F. Turbine of flow meter is
stuck.
A. Regenerate according to the
correct operation requirement.
B. Increase backwash flow rate
and time, clean or change resin.
C. Readjust brine drawing time.
D. According to the test of outlet
water, recount and reset.
E. Regenerate unit by
manual temporary, then
reset regeneration cycle.
F. Disassemble flow meter and
clean it or replace it with a new
turbine.
B. Controller Fault
1. All indictors
display on
front panel.
A. Wiring of front panel with
controller fails to work.
B. Control board is faulty.
C. Transformer damaged.
D. Electrical service not
stable.
A. Check and replace the wiring.
B. Replace control board.
C. Check and replace transformer.
D. Check and adjust electrical
service.
2. No display
on front panel.
A. Wiring of front panel with
controller fails to work.
B. Front panel damaged.
C. Control board damaged.
D. Electricity is interrupted.
A. Check and replace wiring.
B. Replace front panel.
C. Replace control board.
D. Check electricity.