Why does water flow out from the drain or brine pipe after regeneration in my Runxin Control Unit?
- JJudy WoodSep 7, 2025
If water flows out from the drain or brine pipe of your Runxin Control Unit after regeneration, it could be due to foreign material in the valve preventing complete closure; clean the foreign material in the valve body. Hard water mixed in the valve body can also be a cause; change the valve core or sealing ring. If the water pressure is too high, causing the valve to not reach the correct position, reduce the water pressure or use the pressure release function. If, under the Backwash position, the outlet line and brine line are connected, install a check valve or solenoid valve in front of the outlet, or install a liquid level controller in the brine tank.