MODEL 51240B/53540B/53640B/61240B/63540B/63640B
37
In program display mode, press and enter into program set mode.
Press or to adjust the value.
3.5.4. The Steps of Parameter Setting
When time of day “12:12” continuously flash, it reminds
to reset;
1. Press to enter into program display mode; both
and symbol light on,“:”flash;Press , both
and hour value flash, through or to adjust
the hour value;
2. Press again, both and minute value flash,
through or to adjust the minute value;
3. Press and hear a sound “Di”, then finish
adjustment, press to turn back.
1. In control mode display status, press and enter
into program set mode, and 01 value flash;
2. Press or ,set the value to be A-01or A-02
control mode;
3. Press and hear a sound “Di”, then finish
adjustment, press to turn back.
1. In regeneration time display status, press and enter
into program set mode. It shows 02:00. and 02
flash. Press or to adjust the hour value;
2. Press , and 00 flash, press or to adjust
the minute value;
3. Press and hear a sound “Di”, then finish
adjustment, press to turn back.