MODEL 82602-F79A-LCD/82602B-F79B-LCD/82604-F82A-LCD/82604B-F82B-LCD
15
time.
Regenerati
on Time
02:00
00:00~23:59
Suit for A-01/03/11/13/21
Interval
Backwash
Times
00
0~20
Interval backwash times. For
example, F-01:indicate service 2
times, backwash 1 time (Only for
A-11/12/13)
Rinsing
Frequence
00
0~20
Rinsing added time. For example,
F-01:indicate rinse 2 times, service 1
time (Only for A-21)
Water
Treatment
Capacity
10m
3
0~99.99 m
3
Water treatment capacity in one circle
(m
3
) for:A-01/02/03/11/12/13
Backwash
Time
10min
0~99∶59
Backwash time (minute)
Brine &
Slow
Rinse
Time
60min
0~99∶59
Brine & slow rinse time (minute)
Brine Refill
Time
5min
0~99∶59
Brine refill time (minute)
Fast Rinse
Time
10min
0~99∶59
Fast rinse time(minute)
Maximum
Interval
Regenera-
tion Days
30
0~40
Regenerate on the day even though
the available volume of treated water
do not drop to zero (0).
Output
Control
Mode
01
01 or 02
Mode 01: Signal turn on start of
regeneration and shut off end of
regeneration. (Connection refer to the
Figure P4)
Mode 02: Signal available only
intervals of regeneration cycles and
in service. (Connection refer to the
Figure P4)