EasyManua.ls Logo

Runxin F79A-LCD - 2.2. Basic Setting & Usage; A. Parameter specification

Default Icon
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MODEL 82602-F79A-LCD/82602B-F79B-LCD/82604-F82A-LCD/82604B-F82B-LCD
14
2.2. Basic Setting & Usage
A. Parameter specification
Function
Factory
Default
Parameter
Set Range
Instruction
Time of
Day
Rando
m
00:0023:59
Control
Model
A-01
A-01
Down-flow regenerate on the day
although the available volume of
treated water drops to zero (0).
Regeneration starts at the
regeneration time.
A-02
Down-flow regenerate immediately
when the available volume of treated
water drops to zero (0).
A-03
Down-flow regeneration,
regeneration starts at the
regeneration time of the current day
when the available volume of treated
water less than the average water
consumption of last 7 days.
A-11
Up-flow regeneration, regeneration
starts at the regeneration time
although the available volume of
treated water drops to zero (0).
A-12
Up-flow regeneration immediate,
regenerate when the volume of
treated water drops to zero (0).
A-13
Up-flow regeneration, regeneration
starts at the regeneration time of the
current day when the available
volume of treated water less than the
average water consumption of the
last 7 days.
A-21
Filter Type, filter when the service
days reach to zero (0) and the current
time is matched with filter setting

Related product manuals