How to change Regeneration Days Override
Unlock Valve Press Up & Down arrow together for 5 secs until you hear
a beep.
Press the Menu Button.
Press down arrow four times.
H-## will be on the screen. (This is the current setting for the days
override
Press the Menu Button
The Digits will then flash change the number to desired number of days
by pressing the up or Down button & press Menu to save.
Set Water softener Capacity
Unlock Valve Press Up & Down arrow together for 5 secs until you hear
a beep.
Press the Menu Button.
Press down arrow four.
An hourglass and a m³ symbol will light up
Press Menu Button
The digits will then flash, change the number to the amount of capacity
estimated for the ion exchange process in litres the softener will
produce eg:
Feed hardness
(ppm)
Total Capacity
(m³)
50ppm
34m³
70ppm
24 m³
90ppm
18.8 m³
120ppm
14.1 m³
150ppm
11.3 m³
200ppm
8.5m³
250ppm
6.8 m³