11 — English
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE SOLUTION
Work-contacting element does not
depress fully - tool does not operate.
Low nails
Work-contacting element is jammed
Replenish nails
Remove battery and clear debris
Tool operates properly, but fasteners do
not drive fully
Air pressure is too low
Depth of drive isn’t deep enough
Nail is too long for wood hardness
Increase air pressure
Adjust depth of drive
Use nail length that is appropriate for
wood
Tool operates properly, but fasteners are
driven too deep
Air pressure is too high
Depth of drive is too deep
Decrease air pressure
Adjust depth of drive
Tool jams frequently Incorrect nails
Damaged nails
Loose magazine
Dirty magazine
Verify that nails are the correct size
Replace nails
Tighten screws
Clean magazine
Tool stops and LED flashes rapidly Battery is low or has no charge.
Trigger released too early
Recharge battery
Remove battery and reinstall.
Tool has charged battery and LED is
slowly flashing or LED does not turn
off after approximately ten seconds of
non-use.
Tool has malfunctioned Take tool to nearest authorized repair
center
NOTE: ILLUSTRATIONS START ON PAGE 12
AFTER FRENCH AND SPANISH LANGUAGE SECTIONS.
GENERAL MAINTENANCE
Avoid using solvents when cleaning plastic parts. Most
plastics are susceptible to damage from various types of
commercial solvents and can be damaged by their use. Use
clean cloths to remove dirt, dust, oil, grease, etc.
MAINTENANCE
WARNING:
When servicing, use only identical replacement parts.
Use of any other part could create a hazard or cause
product damage.