STARTING/STOPPING
INSTRUCTIONS
These instructions replace the starting and stopping instructions in your opera-
tor’s manual and quick reference guide.
A
Fig. 1
A
Fig. 2
A - Engine switch / fuel valve / choke lever
(interrupteur du moteur / robinet de
carburant / levier d’étrangleur, interruptor del
motor/válvula de combustible/palanca del
anegador)
B - START (DÉMARRAGE, ARRANQUE)
C - RUN (MARCHE, MARCHA)
D - OFF (ARRET, APAGADO)
E - Run switch (interrupteur de marche,
interruptor de encendido)
A
B
C
D
STARTING THE ENGINE
See Figures 1 - 2.
NOTICE:
On a level surface with the engine
off, check the lubricant level before
each use of the generator.
NOTE: If location of generator is not
level, the unit may not start or may shut
down during operation.
Unplug all loads from the generator.
Verify the run switch is in the ON
position.
Move the engine switch/fuel valve/
choke lever to the START position.
NOTE: If engine is warm or the
temperature is above 50˚F, move
the engine switch/fuel valve/choke
lever to the RUN position.
Pull the recoil starting grip until the
engine runs.
NOTE: Do not allow the grip to snap
back after starting return it gently to
its original place.
Allow the engine to run for 15–30
seconds, then move the engine
switch/fuel valve/choke lever to the
RUN position.
RY903600
STOPPING THE ENGINE
See Figure 3.
To stop the engine under normal
operating conditions:
Remove any load from the generator.
Move the engine switch/fuel valve/
choke lever to the OFF position.
To stop the unit quickly in an emer-
gency:
Place the run switch in the OFF
position.
WARNING:
While operating and storing, keep
at least 3 feet of clearance on all
sides of this product, including
overhead. Allow a minimum of 30
minutes of “cool down” time before
storage. Heat created by muffler
and exhaust gases could be hot
enough to cause serious burns
and/or ignite combustible objects.
TECHTRONIC INDUSTRIES
POWER EQUIPMENT
1428 Pearman Dairy Road
Anderson, SC 29625, USA
Phone 1-800-860-4050
www.ryobitools.com
991000815
11-20-15 (REV:01)
A - Recoil starter grip (poignée de démarreur à
rappel, mango del arrancador retráctil)
E

Other manuals for Ryobi RY903600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ryobi RY903600 and is the answer not in the manual?

Ryobi RY903600 Specifications

General IconGeneral
TypePortable Generator
Engine Type4-Stroke OHV
Starting SystemRecoil
Fuel TypeGasoline
Rated Wattage3600 Watts
AC Output120V
DC Output12V

Related product manuals