5. AUXILIARY
FUNCTIONS
MENU
5.3 MENU DESCRIPTION
What you see
on the display
DescripƟon and Comments
Normal
Mode
Insp
Mode
Visibility
Condition
Range
Default
Value
V4.00.K Firmware version + revision number V V
Normal
FLxx
Li/Door Status + Floor number V V
View Faults
(Fatal=--)
View faults log If faults exist
Homing trip? Request a homing trip V V
Simplex(1)Full
Swinging
Li summary V V
Simulate calls On-board calls registration
V/A
NV
/
NA
Inspecon
operaon
On-board inspecon operaon
NV/
NA
V/A
Boards detected
On Bus
Used in group mode
DT is
connected
Enter Password Access the menu V/A V/A
Empty Fault Log Clears the fault log if faults exist
Light Time Car light turn off delay in sec A A N/A 5 to 99” 10”
Floor Stopping
Time
Time between travel in sec A A N/A 1.0 to 9.9” 3.0”
Parking Door The parking status of the door A A Auto/Half Auto door Opened/Closed Closed
Door
Nudging/Obst
When enabled, the
RE OPN
input is
bypassed to clear any obstacle blocking
the door/ When disabled and the door is
held open, it is considered to be
obstructed aer this delay
A A N/A Ena/ Dis, 5 to 99” Dis, 90”
Hydraulic Star
Time
Star starting time of the hydraulic pump A A Hydraulic elevator 0.0 to 9.9” 1.0”
VVVF Start
Delay
The delay in sec between providing
direcon and speed reference outputs
A A VVVF drive -9.9 to 9.9” 0.0”
VVVF/ Hyd Stop
Delay
The delay in sec between removing
direcon and speed reference outputs
A A VVVF drive/Hydraulic -9.9 to 9.9” 3.0”
Gong Time The gong me in seconds A A
Spare1 or Spare2 or
Spare3 or Spare4
funcon=gong, CC+,
CC-, HC+, HC-
0.0 to 7.5” 3.0”
Minimum Load
When this feature is enabled, car calls are
canceled if car stops twice on a car call
and no passengers exit car
A A N/A Disabled/Enabled Disabled
Main Landing
Sets the landing floor along with the delay
before making a main landing trip given
that the elevator has no calls to serve
A A N/A
None, 0… 31- 0’10” to
30’59”
None
Power On
Homing
When enabled, the elevator makes a
homing trip upon every power-on
When disabled following power on and if
li is not parked on a floor , the controller
will take it to the nearest floor traveling in
the same direcon prior to power failure
When set to NoDZ and the li is on a
floor, no action is taken. Otherwise, li
will do homing trip upon power-on
A A N/A Disabled/Enabled/ NoDZ Disabled
V means visible
A means accessible
NV means not visible
NA means not accessible
If there are 2 close oors or the elevator slips more than ½ distance of the oor, “Power On Homing” must be set to enabled