The s::can con::cube D-315 is a versatile, high-performance, power-efficient industrial computer designed for on-line operation of s::can spectrometer probes (e.g., spectro::lyser, nitro::lyser, carbo::lyser, etc.), s::can ISE probes (e.g., ammo::lyser), and other s::can sensors. It integrates all tasks of a complete monitoring station, including data acquisition, processing, storage, and communication. The con::cube D-315 is designed for continuous, unattended operation in industrial environments, offering robust performance and comprehensive data management capabilities.
Function Description
The con::cube D-315 serves as a central control and data processing unit for s::can measurement systems. Its primary functions include:
- Spectrometer Probe Integration: It supports the integration of various s::can spectrometer probes, such as spectro::lyser, nitro::lyser, and carbo::lyser, for detailed water quality analysis.
- ISE Probe and Sensor Integration: The device can connect to s::can ISE probes (e.g., ammo::lyser) and other s::can sensors, expanding its measurement capabilities.
- Simple Initialisation and Parameterisation: The con::cube D-315 allows for easy setup and configuration of s::can infrastructure, including automatic cleaning devices, ensuring efficient operation.
- Parameter Calibration: It facilitates the calibration of spectrometer probes, ISE probes, and sensors, ensuring accurate and reliable measurement results.
- Local Database Storage: Measurement results and all other station information are stored in a local database, providing a secure and accessible record of data.
- Data Transfer via Modbus RTU/TCP Interface: The device supports data transfer via Modbus RTU/TCP, enabling integration with existing control systems.
- Data Transfer via Profibus DP Interface: It offers data transfer via Profibus DP, a common industrial communication protocol.
- Data Transfer via SDI12 Interface: The con::cube D-315 can transfer data via SDI12, suitable for environmental monitoring applications.
- Data Transfer via FTP File Transfer: FTP file transfer allows for easy and secure data retrieval.
- Potential Free Digital Relay Output: The device includes a potential-free digital relay output for controlling external devices based on measurement results.
- External Sensor Signal Integration: It supports the integration of external sensor signals via RS485 input, analog input, and digital input, enhancing its versatility.
- Network Connectivity: The con::cube D-315 offers network connectivity via Ethernet, WLAN, or optional 3G modem, enabling remote monitoring and data access.
- Remote Control and Monitoring: The device can be remotely controlled and monitored from a PC, tablet, or smartphone via web-browser or VNC, providing flexibility in operation.
- Data Synchronisation: It supports data synchronisation to central data collection systems via Ethernet, WLAN, or optional 3G modem.
- Display of Current and Historical Readings: The integrated graphical display shows current and historical measurement data, providing immediate insights into water quality.
- Alarming: The device features alarming capabilities based on water quality monitored, alerting users to critical changes.
The con::cube D-315 is equipped with an embedded operation software (moni::tool) that can be operated via a color-graphical display with touch functionality. The software starts automatically when the con::cube is powered up. It collects readings from probes and sensors, displays data, stores all information, and makes it available for further use.
Important Technical Specifications
The con::cube D-315 is designed for robust performance in various environments. Key technical specifications include:
- Power Supply:
- D-315-230: Station control terminal with 100-240 VAC, 50-60 Hz power supply.
- D-315-024: Station control terminal with 10-36 VDC power supply.
- Display: D-315-TOUCH model with a display and touch screen input module.
- Operating System: 3G modem (OS: Linux).
- Profibus Module: D-315-OUT-PROFIBUS (Profibus DP output module).
- SDI12 Module: D-315-OUT-SDI12 (SDI12 output module).
- Analog Outputs:
- D-315-OUT-MA: 2 analog outputs (output module).
- D-315-OUT-RELAY: 4 digital outputs (output module).
- Analog Inputs:
- D-315-IN-MA: 2 analog inputs for integration of third-party readings (input module).
- D-315-IN-RELAY: 2 digital inputs for integration of third-party readings (input module).
- Antenna Connections:
- D-315-ANTENNA-PLUG: Internal antenna adapter cable and connector.
- D-315-ANTENNA-PRO: External, high range antenna, incl. 10 m extension cable.
- Linux Application: D-303-LX (Linux application for fix installed OS).
- Complete License: S-20-MVA (complete license including moni::tool (all features), vali::tool and ana::tool).
- Dimensions Housing: 280 / 209 / 85 mm (W/H/D).
- Required Space: 290 / 280 / 240 mm (W/H/D).
- Weight: Approx. 4 kg.
- Operation Temperature: -20 to 50°C (-4 to 122°F).
- Storage Temperature: -20 to 60°C (-4 to 140°F).
- Humidity: 5 to 90%.
- Material Housing: Aluminum alloy, powder coated.
- Environment Rating (IP): IP 65.
- Environmental Conditions: Altitude up to 2000 m, overvoltage category II, pollution degree 2.
- Mounting: 4 x M5 thread holes on backside, 2 mounting brackets and 4 screws (included in delivery) for direct mounting on panels (F-501) or wall mounting from front side.
- Required Galvanic Isolation of Power Input: 3.0 kV (D-315-230), 1.5 kV (D-315-024).
- Power Consumption: 1.5 W (typical) in sleep mode, 10 W (max.) / 20 W (max.) not fully equipped, 30 W (typical) / 60 W (max.) fully equipped.
- Electrical Potential: Grounding for D-315-024 and D-315-230. Max. 0.1 Ohm PE power supply to site's earth grounding. Max. 0.5 Ohm PE power supply to process medium.
- Conformity: EN 61010-1, EN 61000-6-1, EN 61000-6-4 R10.08, CISPR22/CISPR24, C22.2 No. 61010-1-04 R2009.
- Internal Battery: CR2032, 3V Lithium battery for real time clock (RTC).
- Connection of s::can Spectrometer Probe: 1 x MIL-Spec (IP 67, RS485, 12 VDC) galvanically isolated 1 kV internal network termination 120 Ohm.
- Connection of s::can ISE Probes or s::can Sensors: 4 x sys plug connector (IP 67, RS485, 12 VDC) galvanically isolated 1 kV internal network termination 120 Ohm.
- RS485: Galvanically isolated 1 kV internal network termination 120 Ohm.
- Display: VGA TFT color display (800x480), 7 inches (approx. 150 x 90 mm).
- User Interface (on device itself): USB (keyboard, mouse), touch screen.
- User Interface (remote control): Web-browser (TCP/IP), VNC (TCP/IP).
- Network Connection (TCP/IP): WLAN / WiFi 802.11n a/b/g (300Mb/s), Ethernet LAN (100 Mb/s, RJ45), 3G modem.
- USB: USB connector (type A, 2.0) for data transfer, software update, keyboard, mouse.
- Operating System: Linux, installed ex works (D-303-LX).
- Main Memory: 1 GB RAM.
- Onboard Memory: 4 GB.
- Functional Display (LED): 4 x LED (blue / red) linked to digital OUT 5 by default.
- Interface to SCADA: Modbus RTU, Modbus TCP. Max. 8 parameters.
- Interface to SCADA (optional): Profibus DP for max. 8 parameters (Slave according IEC 61158, up to 11 Mbits, DPv1, Baudrate bis 12 Mbaud). D-315-OUT-PROFIBUS (blue module), address = 1.
- SDI12 out for max. 8 parameters: D-315-OUT-SDI12.
- Analog OUT (4 to 20 mA active): Resolution = 12bit (5 µA), Accuracy = 30 µA, Max. load = 500 Ohm, Galvanic isolation = 1 kV. D-315-OUT-MA (black module).
- Analog IN (4 to 20 mA): Input impedance = 100 Ohm, Galvanic isolation = 1 kV, Resolution = 12 bit (1 µA). D-315-IN-MA (red module).
- 3G Modem (optional): 3G: 900 and 2100 MHz, 3G: 850, 1900 and 2100 MHz, EDGE/GPRS: 850, 900, 1800 and 1900 MHz. D-315-3G-EU, D-315-3G-US.
- Digital OUT (optional) (relay on): Max: 230 V / 500 VA (AC 15), 24 V / 100 W / 2 A (DC 1), Min: 5 V / 100 mA. 1 module normally open COM-3, address 33.
- Digital OUT sum error (relay on): Max: 230 V / 500 VA (AC 15), 24 V / 100 W / 2 A (DC 1), Min: 5 V / 100 mA. 1 module normally open COM-3, address 33, LED: red = open, blue = closed.
- Digital IN: Logic levels: low < 5 V, high > 10 V, Max. voltage = 24 V, Galvanic isolation > 1 kV. D-315-IN-RELAY (white module).
- Digital OUT (relay change): For 2 cleaning devices.
- Power supply output 12 V: 12 VDC, max. 8 W.
Usage Features
The con::cube D-315 is designed for user-friendly operation and flexible deployment:
- Graphical Display with Touch Screen: The integrated 7-inch VGA TFT color display with touch functionality provides an intuitive interface for monitoring and control.
- Easy Installation: The device can be mounted on panels or walls using the provided brackets and screws. It is recommended to ensure correct orientation of mounting rails and proper water flow.
- Terminal Connections: Clearly labeled terminal connections for power supply, spectrometer probes, ISE probes/sensors, Ethernet, USB, and optional I/O modules simplify wiring.
- SIM Card Slot: An internal SIM card slot allows for easy integration of 3G modem functionality for remote connectivity.
- Web-Browser and VNC Remote Access: The moni::tool software can be accessed via a standard web browser or VNC client, enabling remote operation from any computer, tablet, or smartphone. This allows for viewing measurement data, changing settings, and performing calibrations without direct physical access to the device.
- User Management: The system supports user login with administrator and user roles, ensuring secure access and control.
- Network Configuration: Comprehensive network settings allow for configuration of Ethernet, WLAN, 3G modem, and VPN connections, providing flexible connectivity options.
- Data Storage and Transfer: Measurement data is stored locally and can be transferred via various protocols like FTP, SSH, Modbus, and SDI12, facilitating integration with existing data management systems.
- Data Types: The device supports various data types for measurement results, including character, bitmask, signed and unsigned integers, floats, and timestamps, ensuring compatibility with different analytical needs.
- Modbus Interface: The con::cube D-315 is equipped with a Modbus interface, supporting RTU or TCP/IP protocols, for seamless integration with SCADA systems and other industrial control devices. It provides detailed mapping of device-specific input and holding registers.
- Profibus DP Interface: For systems requiring Profibus DP, the con::cube D-315 offers a dedicated interface with mapping for device status and measurement parameters.
- SDI12 Interface: The SDI12 interface allows for communication with SDI12-compatible fieldbus devices, enabling data transfer and control commands.
- Functional Check: The manual provides a detailed guide for routine functional checks, covering power supply, system running status, automatic measurement active status, system status, system stability, installation, function of automatic cleaning, efficiency of automatic cleaning, and data transfer. This helps users ensure the device is operating correctly and efficiently.
Maintenance Features
The con::cube D-315 is designed for ease of maintenance, ensuring long-term reliability and performance:
- Cleaning: The device housing is made of aluminum alloy and can be cleaned with a wet cloth and drinking water, or mild detergents.
- Desiccant Package: An internal desiccant package helps to prevent condensation and maintain optimal humidity inside the housing. The desiccant packages are replaceable and should be exchanged regularly (typically every time the housing cover is opened).
- Housing: The housing is designed for IP 65 protection, and gaskets and cable glands ensure a tight seal. Regular inspection of the housing cover and cable glands is recommended to maintain the IP rating.
- Calibration Touch Screen: The touch screen can be calibrated to ensure accurate input. This can be done directly on the device or remotely via VNC Viewer.
- Device Settings: Device settings can be accessed and modified through the s::can logo in the lower right-hand side of the screen.
- Software Update: Software updates can be performed by contacting s::can sales partner or customer support.
- Return Consignment (RMA): In case of device malfunction, an RMA process is available for repair or replacement.
- Automatic Cleaning Valve: The device includes an automatic cleaning valve (B-44) for probes and sensors, which requires periodic maintenance. This involves checking the valve for proper function and ensuring the cleaning solution is adequate.
- Spare Parts: Desiccant packages (B-43-2), touch pens (D-312-PEN), and other optional modules are available as spare parts, facilitating easy replacement and maintenance.
- Power Supply Cord: The power supply cord (C-31-EU or C-31-US) is a replaceable component.
- External Antenna: The external antenna (D-315-ANTENNA-PRO) and its extension cable are also replaceable.
- Automatic Cleaning Valve: The automatic cleaning valve (B-44) is a replaceable component, and its maintenance includes checking for proper function and ensuring the cleaning solution is adequate.
- Modular Design: The con::cube D-315 features a modular design, allowing for easy replacement of individual components like the Gateway to 3G Modem, Analog Output Module, Digital Output Module, Profibus DP Output Module, SDI12 Output Module, Analog Input Module, and Digital Input Module. This modularity simplifies troubleshooting and repair.
The con::cube D-315 is a robust and intelligent solution for water quality monitoring, offering comprehensive features for data acquisition, processing, and communication, with a strong emphasis on reliability and ease of maintenance.