11 TROUBLESHOOTING
Fault Cause Solution
The fire does not burn well Wood is too damp Check, max. residual moisture 20%
Wrong fuel Only use the permitted fuels for the appliance
Chimney draught too weak (min. 12 Pa) Check the outlet is airtight
Light fire in the chimney
Close any open doors on other appliances
connected to the chimney
Seal any cleaning hatches in the chimney
If necessary, clean the connector
Insufficient combustion air Check air flow and diameter of flue connections
Check ventilation fittings and extractor hood, if
necessary open windows
Glass gets dirty quickly Wood is too damp Check, max. residual moisture 20%
Wrong fuel Fuel not small enough, ensure max. size
Only use the permitted fuels for the appliance
Too much wood used Do not use more 2 or 3 pieces of wood at once
Insufficient combustion air Connect combustion air feed directly to the
appliance and extract to the circulation grid
or directly to outside
Check diameter of circulation
Check ventilation fittings and extractor hood, if
necessary open windows
There is a paint smell and smoke The coating is drying out There is a smell when the stove gets very hot.
Disappears after a while.
Condensation Large temperature difference Open the door a chink while the stove warms
up. Do not leave the appliance unattended!
Smoke nuisance Chimney draught too weak (min. 12 Pa) Check the outlet is airtight
Light fire in the chimney
Close any open doors on other appliances
connected to the chimney
Seal any cleaning hatches in the chimney
If necessary, clean the connector
Fuel is not entirely used up Fuel should only be added when there is no
orange flame visible in the stove.
Chimney fire Wrong fuel
Overloading
Poor maintenance
Shut off the air flow immediately and call the fire
brigade