EasyManua.ls Logo

Sabiana JANUS 05 - User Manual

Sabiana JANUS 05
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Via Piave, 53 20011 Corbetta (MI) ITALY
Tel. +39.02.97203.1 ric. autom. Fax +39.02.9777282 - +39.02.9772820
E-mail: info@sabiana.it Internet: www.sabiana.it
MANUALE DI INSTALLAZIONE
E MANUTENZIONE DEGLI
AEROCONDIZIONATORI
INSTALLATION AND
MAINTENANCE MANUAL
FOR AIR CONDITIONERS
INSTALLATIONS- UND
WARTUNGSANLEITUNG
FÜR KLIMAGERÄTE
MANUEL D’INSTALLATION
ET D’ENTRETIEN DES
AÈROCONDITIONNEURS
MANUAL DE INSTALACION Y
MANTENIMIENTO DE LOS
ACONDICIONADORES DE AIRE
03/2020
JANUS 05JANUS 05
Cod. 4050668
Question and Answer IconNeed help?

Do you have a question about the Sabiana JANUS 05 and is the answer not in the manual?

Summary

USE AND PRESERVATION OF THE MANUAL

Manual Purpose and Availability

Describes the manual's intended audience, purpose, and importance for consultation.

Manual Preservation and Manufacturer Responsibility

Covers proper storage, replacement, and the manufacturer's disclaimer for misuse.

APPLIANCE PURPOSE AND LIMITATIONS

Before Installation: Manual Review

Emphasizes the necessity of carefully reading the manual before commencing installation.

Unit Description and Intended Application

Details the unit's design for industrial heating/cooling and its primary functions.

Prohibited Installation Environments

Lists unsuitable installation locations and atmospheres to prevent damage or hazards.

Water Supply and Environmental Checks

Specifies water requirements and necessary environmental checks to prevent corrosion.

TRANSPORT AND UNIT IDENTIFICATION

Unpacking and Initial Inspection

Guidelines for checking the unit for damage and verifying it matches the order after unpacking.

Unit Identification Label Location

Specifies the location of the unit's identification label for easy reference.

SECURITY RULES

Earthing Connection Requirement

Ensures the appliance's earthing connection is properly established for safety.

Prohibited Supply Types: Steam

Prohibits supplying the appliance with steam, mandating only water.

Frost Protection for Batteries

Advises on protecting the unit's batteries from potential frost damage.

OPERATING LIMITS

Heat Exchanger and Fan Coil Specifications

Lists maximum and minimum fluid temperatures and maximum working pressure.

WASTE DISPOSAL

Product Disposal and Environmental Compliance

Emphasizes disposal according to environmental laws and the WEEE directive.

Recycling Symbol Meaning

Explains the crossed-out bin symbol indicating mandatory separate waste collection.

TECHNICAL CHARACTERISTICS

Sound Level and Fan Speed

Details the sound pressure level and fan rotational speeds.

Operational Safety Precautions

Warns against approaching the moving fan and recommends gloves for disassembly.

Dehumidification Functionality Explained

Explains the unit's dehumidification function and potential condensate release.

Cooling Operation Speed Recommendation

Advises using only low speed for cooling operations to ensure proper function.

INSTALLATION

Installation Safety and Clearance

Alerts against debris entry and advises on required maintenance clearance for motor and fan.

Mounting Requirements and Slope

Specifies wall mounting, correct condensate drain slope, and exclusion of ceiling installation.

Appliance Fixing Methods

Outlines general methods for fixing the appliance, including optional wall brackets.

Mounting with Optional Wall Brackets

Details the steps for installing wall brackets and securely mounting the unit.

WATER CONNECTION

Open Circuit Water Treatment

Advises filtering water in open circuits and taking measures to prevent corrosion.

Sealing and Connection Components

Recommends specific materials and components for making secure water connections.

Condensate Drain Installation

Recommends fitting a siphon and ensuring proper slope for the condensate drain pipe.

Water Supply Restrictions

Mandates supply with hot or cold water only, prohibiting steam.

ELECTRICAL CONNECTION

Pre-Connection Safety Procedures

Emphasizes ensuring the switch is OFF and a suitable disconnection switch is present.

Earthing and Motor Specifications

Covers earthing verification and details of the three-phase motor, including protection.

Motor Speed Control via Wiring

Explains how motor speed is adjusted by changing the wiring connection from delta to star.

CLEANING AND MAINTENANCE

Safety: Power Disconnection Before Maintenance

Stresses the critical importance of disconnecting the appliance from the power source before any cleaning or maintenance.

Authorized Personnel and Motor Care

States only trained personnel can perform maintenance, and motors require no upkeep.

Heat Exchanger and Fan Maintenance

Details regular checks for heat exchanger fins and fan motor/support security.

Spare Parts Ordering Information

Instructs to always provide the appliance model and component description when ordering spare parts.

TROUBLE-SHOOTING

Motor Not Rotating

Addresses the issue of the motor failing to start and its primary cause.

Noisy Ventilator Group

Guides on diagnosing and resolving excessive noise from the fan unit.

EU DECLARATION OF CONFORMITY

Product and Model Identification

Identifies the specific product and model numbers covered by this declaration.

Conformity to EU Standards and Legislation

Lists the relevant EU standards and legislative directives the product complies with.

Technical File and Declaration Date

Specifies the location of the technical file and the date of the declaration's issuance.

Sabiana JANUS 05 Specifications

General IconGeneral
MountingWall Mounted
Energy Efficiency Ratio (EER)3.21
Coefficient of Performance (COP)3.61
RefrigerantR410A
Sound Pressure Level (Indoor)42 dB(A)
Power Supply230V, 50Hz