4 TECHNICAL INFORMATION
Characteristic
Unity
Saey Cross
Carbon emission ( at 13% O2 )
%
0,09
Emission dust particles ( at 13% O2 )
mg/Nm³
33
Efficiency
%
78
Nominal power
kW
7
Flue gas temperature
°C
192
Draft at nominal consumption
g/s
6,5
Draft limits
Pa
12 22
Fresh air supply
m³/h
17,8
Dimensions and weight
Height
mm
764
Width at bottom / top
mm
784 / 634
Depth at the bottom / top
mm
540 / 452
Connection above or behind
Ø mm
130
Combustion air connection
Ø mm
80
Weight
mm
212
Fuel
Fuel
Wood and briquettes
Max capacity wood
kg
1,6
Nominal consumption
kg/h
2
Max load wood briquettes
kg
1,5
Nominal consumption
kg/h
1,9
Max. log length
cm
25
Max. diameter/size
cm
35
Top connection Rear connection
618 mm
130 mm