7.3 (a) The Blueberry controller has two different setting
programs, Standard and Eco mode generation.
(b) Standard Mode: The Blueberry controller will raise the
temperature to 130°F (or the programmed temperature)
and then switch off. It will automatically start again
to raise the water temperature once it falls to 120°F.
(or 10°F lower than programmed temperature).
(c) To view the set point temperature, press the P button.
SP is displayed alternatively with the set temperature.
Using the buttons with the arrow pointing upwards
/ downwards we can increase / reduce the set point
temperature. Once set, press the “P” button or leave and
the program will revert to displaying the actual water
temperature.Thisisdisplayedingures14&15
(d) The temperature range is from 50 to 130ºF. The unit will
raise the temperature to 130°F (or the programmed
temperature) and then switch off. It will automatically start
to raise the water temperature once it falls to 130°F. (or
10°F lower than programmed temperature).
(e) Standard Mode also incorporates an Anti-legionella
cycle, this is is actuated automatically, once a
week (every Monday between 5:00 to 7:00) using
the integral real-time clock within the blueberry
controller.
(f) During the Antilegionalla mode the controller will
automatically heat water within the cylinder to 140°F as an
anti-legionella measure. It uses the heat pump not the
immersion heater to heat the water to this temperature.
7.4 (a) Eco mode is activated when the Blueberry controller receives
asignalfromtheinstalled2conductorwire(refertosection6)
that the connected PV inverter is generating electricity.
(b) When Eco mode is active, The Blueberry controller displays
the temperature of the water at any time but will
intermittentlyash‘Eco’acrossthecontrollerscreen.
(c) When in Eco mode the Blueberry controller will raise the
temperature to 140°F and then switch off. It will automatically
start again to raise the water temperature once it falls to 130°F.
(d) When the Blueberry controller stops receiving a signal
from the installed 2 conductor wire that the connected
PV inverter is generating electricity, the Blueberry Controller
will exit Eco Mode and enter standard Mode.