9
Copyright. Sygnal 2018
8. Use or to alter the start time to the correct value (in 10 minute intervals).
9. Press SET to proceed to the stop time. The top line will scroll: Program stop: ALL zones
10. Use or to alter the stop time then press SET to complete setting the global timer program
and return to normal operation.
2.12 Setting Individual Zone Timer Programs
1. Press ZONE or or to select the required zone.
2. Press CLOCK to display the current program days for that zone.
3. Press or to select Program A or Program B then press SET.
4. The top line will scroll Program Days:Zone x.
5. A CAPITAL letter indicates that the zone on/off times will apply to that zone on that day. Press
to activate, or to deactivate each day, then press SET to move to the next day. Repeat for each day.
6. Press SET after the final day value to enter the start time. If no days have been activated the
configuration routine will exit at this point. If there are valid days the top line will scroll Program
start: Zone x.
7. Use or to alter the start time to the correct value (in 10 minute intervals).
8. Press SET to save the start time and proceed to the stop time. The top line will scroll Program
stop: Zone x
9. Use or to alter the stop time. The top line will scroll Program stop: Zone x.
10. Repeat for each zone as required.
2.13 Holiday, Away, Disable Time Clock Programs
1. Select the Global screen.
2. Press CLOCK to display the current time.
3. Press to access TC Enable menu.
4. Use or to select Yes? Or No? and press SET.
5. TC Off will scroll with the system information when No? is selected.
Stop: AL
05:30 pm
Ram Days
sMTWTFs
10:12pm Tu
Off