EasyManua.ls Logo

Sailfish 236 CC - Marine Head Usage: Water Level and Lockout; Correct Water Level Usage; Flush Lockout Feature

Default Icon
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
03/20/2017 Sailsh236CCOwner’sManual|sailshboats.com 28
Optional Marine Head - Tecma Nano Premium Plus
Correct Water Level
Usage
Water usage is not adjustable in the
Marine Mode.
The recommended water level is
5” below the toilet rim. To set this
in the programming mode, release
your ngers 4-5 seconds after water
begins owing into the toilet. Setting
the water deeper than this level
creates excessive water use and lls
the holding tank too quickly.
CAUTION: Raw Water systems are
designed to perform optimally with
pumps rated at approximately 3.0
gallons per minute (similar to the
pump supplied). Lower rated pumps
will provide a less vigorous ush,
while use of higher rated pumps will
cause excessive water consumption.
Emptying the Bowl
To empty bowl without adding water
or starting a ush sequence, push
and hold both buttons simultaneously
until bowl contents are discharged.
Pushing either button returns toilet to
normal operation.
NOTE: Holding more than 5 seconds
will start the water level programming
mode.
CAUTION: Rell the toilet as soon
as possible after emptying the bowl.
Leaving water out of the trap can
result in objectionable odors.
Flush Lockout
This toilet is equipped with an
electronic holding tank level sensing
feature that automatically prevents
FLUSH button operation when the
holding tank is full and thus, prevents
waste overow.
Single Flush Override
of Flush Lockout
If holding tank is full, system will not
allow a ush to occur. (If a ush is
taking place, it will be completed.)
Toilet will NOT ush automatically
when the tank level indicator is red.
This can be overridden by holding the
FLUSH button for about 8 seconds.
This initiates one ush and reacti-
vates ush lockout.
This override function is intended for
emergency use only. Because the
sensor is not located at the exact top
of a tank, the override function can be
used about 5 times before overow-
ing. Size and shape of the holding
tank determine the actual number of
times it can be used. Contact manu-
facturer for more detailed information.
WARNING: An excess of ushes after

Related product manuals