Light Commercial R410A on-off S13-01.01.13en
SIB-100DAY
Cooling
Heating
Remark:
TC : Total capacity ; kW
SC: Sensible heat capacity ; kW
Input: Input power ; kW
Indoor Units. HSP Duct Type 73
Heating
Outdoor conditions
Indoor Conditions
(DB)
(kW)
24/18ºC
DB/WB
7/6ºC
DB/WB
2/1ºC
DB/WB
-5/-6ºC
DB/WB
-7/-8ºC
DB/WB
15ºC
TC
15.60 12.60 10.32 9.36 8.76
Input
4.25 3.66 3.15 2.95 2.79
20ºC
TC
15.12
12.00
9.72 9.12 8.40
Input
4.64
3.93
3.46 3.19 2.99
27ºC
TC
14.16 11.28 9.12 8.88 7.92
Input
4.92 4.25 3.74 3.46 3.23
Cooling Outdoor conditions (DB)
Indoor Conditions (kW) 18ºC 21ºC 28ºC 35ºC 43ºC
21/15ºC DB/WB
TC 11.13 10.82 10.29 9.77 9.35
SC 8.12 8.00 7.92 7.81 7.85
Input 3.19 3.31 3.59 3.75 3.87
24/17ºC DB/WB
TC 11.45 11.13 10.61 10.08 9.45
SC 8.47 8.35 8.27 8.16 7.94
Input 3.39 3.51 3.75 3.91 4.11
27/19ºC DB/WB
TC 11.66 11.34 10.82 10.50 9.77
SC 8.51 8.39 8.33 8.19 8.01
Input 3.47 3.59 3.79 3.99 4.19
32/23ºC DB/WB
TC 11.97 11.55 11.13 10.92 10.08
SC 10.05 9.82 9.68 9.61 9.37
Input 3.63 3.75 3.91 4.19 4.35