The fittings for the terminal boxes can be found in Table 2: :
Table 2: Fitting of terminal boxes
1) The light indicator signals are carried by a common fibre optic cable to the cover, so that the signals are visible
from outside.
2) When mains voltage is present, the lamp lights up green
The direction of rotation indicator light lights up green when mains voltage is
present and the direction of rotation is correct; if the direction of rotation is
incorrect, the indicator light goes out (see chapter “Commissioning”).
7 Installation and electrical connection
DANGER! Danger of death!
Incorrect installation and inexpert electrical connection can pose a risk of
fatal injury. Danger from electrical current must be eliminated.
The installation and electrical connection may only be carried out by quali-
fied personnel in accordance with the applicable regulations!
Accident prevention regulations must be observed!
Comply with the regulations of the local power supply company!
Pumps with pre-assembled cable:
Never pull on the pump cable
Do not kink the cable.
Do not place any objects on the cable
7.1 Installation
WARNING! Danger of personal injury!
Incorrect installation can result in personal injury.
There is a crush hazard
There is an injury hazard due to sharp edges/burrs. Wear appropriate protec-
tive clothing (e.g. safety gloves)!
There is an injury hazard due to the pump/the motor falling. Use suitable lift-
ing gear to secure the pump/motor against falling.
CAUTION! Risk of damage!
Incorrect installation can result in damage to the product.
Only use qualified personnel for the installation work!
Observe national and regional regulations!
Terminal box
type
Direction of rotation
indicator light
Variable speed control
4a - Speed selection switch, 3-step
4b
2)
internal (Fig. 4b) Change-over switch, 3-step
4c
1)2)
external (Fig. 6) Change-over switch, 3-step
4d
2)
external (Fig. 4d) Change-over switch, 2-step