5.1 Fast programming
5. PROGRAMMING
ON
IDIOMA
ESPANOL V 2.0
PRESSING IT FOR MORE THAN 1s
YOU GO OUT OF THE SETUP
AND THE PARAMETERS
ARE STORED IN THE MEMORY
IGNITION
CONTROL PANEL
COSFI < 0.45
ENTER MANUALLY
COSFI > 1.00
ENTER MANUALLY
IT INDICATES THAT
THE COSφ MEASURED
IS LESS THAN 0.45
(POSSIBLE DRY
RUNNING)
NO LOAD MAXIMUM CURRENT
> -- A
THE MOTHERBOARD
DOES NOT DETECT
ANY CONNECTED
MOTOR
THE ABSORBED
CURRENT EXCEEDS
THE MAXIMUM
ALLOWED THRESHOLD
IT INDICATES THAT
THE COSφ MEASURED
IS MORE THAN 1.00
(COSφ READING
ANOMALY)
POSSIBLE ANOMALIES DURING THE AUTO-LEARNING PHASE
AUTO - LEARNING
ENTER TO START
AUTO - LEARN. 0 %
CF 0.80 13.2 A
AUTO - LEARNING
COMPLETED
IN THIS STAGE THE
MOTHERBOARD STARTS
FOR APPROXIMATELY 30s
THE MOTOR RECORDING
THE PARAMETERS
AUTOMATICALLY
THE MOTHERBOARD HAS
CORRECTLY PERFORMED
THE AUTO-LEARNING
PROCEDURE
It is used to scroll forward through the setup pages
It is used to increase the value of a parameter
It is used to scroll back through the setup pages
It is used to reduce the value of a parameter
Pressed it allows to enter the selected parameter
Pressed confirms the set value
Pressed it exits the parameter
22