(1) Unclose the earphone cap (without removing) in the direction of
the arrow
(2) Insert the earphone or microphone
2. Removal of the external earphone or microphone
You can pull out the external earphone or microphone to remove it.
Note: The use of an external earphone or microphone will affect the
waterproof performance of the transceiver.
Operation Guide
Item
1
2
3
4
Squelch Level Selection
BEP
Keypad Tone
ON/OFF
Display
GRP
VOX
SQL
Description
b.Meun Selecting List
Setting content
0-19
OFF 1-9
1-9
Group channel setting
Voice Operation
4
5
6
BEP
CMP
SCA
After pressing MENU into function menu and GRP will be shown on display, press OK key then you can select 0-19
through by or ▼, then press OK key again the new GRP channel is fix. press the EXIT key to give up setting
After pressing MENU into function menu and choice VOX, press OK key then you can select 1-9 and off through by
or ▼, then press OK key again, press the EXIT key to give up setting. Level 9 small voice can open transimt.
1GRP (Group Channel) Setting
2VOX Setting
Keypad
Tone
Voice Compression
Scrambler Function
ON/OFF
ON/OFF
ON/OFF
3SQL ( Squelch Level Selection ) Setting