10 | SAMLEX AMERICA INC.
SECTION 3 | Operation
3.2.2 Power OFF - AC INPUT IS NOT PRESENT
NOTE: If the EVO™ Inverter/Charger has AC input voltage over 70 ± 5 VAC available at AC Input, the Power
OFF function is disabled and the unit will remain in the ON condition if the power off sequence is attempted.
The AC input must be removed before the unit can be powered OFF.
The sequence given below is applicable when no AC input is present and the unit is powered OFF.
Press On/Off Key and hold for 5 seconds to turn OFF the EVO™ Inverter/Charger.
When EVO™ Inverter Charger is ON and the On/Off key is pressed and held for
minimum of 5 seconds, the LCD screen will show “POWER OFF !” and both the
Status and Alarm LEDs will turn ON. Now release the On/Off key (please note
that Power Off sequence will be completed and display “POWER OFF !” will
disappear only when the On/Off key is released).
3.3 DATE AND TIME SETUP
Set date and time as per procedure given at Section 4.9: “Group 6 Parameter Setup: Time Setting”.
3.4 STANDBY MODE
When the EVO™ is in Standby Mode, inverting or charging / AC pass through will be suspended.
INFO
Standby Mode may be used to temporary halt normal operation of the Inverter/Charger without switching OFF
the unit completely.
For the Standby Mode to be switched ON, the EVO™ should be in ON condition and should be operating in one of the
4 Operating Modes – “Inverting” or “Charging”, “Power Saving” or "Online" (See Fig 3.1). When Standby Mode is
switched ON, the EVO™ will suspend its Operating Mode.
Standby Mode is toggled between ON and OFF conditions as detailed at Section 3.4.1.
3.4.1 Procedure to Enter and Exit Standby Mode / Status Display in Standby Mode
INFO
• EVO-RC-PLUS Remote Control will be required to be connected to the EVO Inverter-Charger Unit to
enter Standby Mode as explained at Section 3.4.1.1 below. Once Standby Mode has been entered using
EVO-RC-PLUS Remote Control, it can ALSO be switched off using the On/Off Push Button on the front
panel of the EVO Inverter-Charger Unit (See Section 3.4.1.2)
• If EVO-RC-PLUS Remote Control has NOT been connected to the EVO Inverter-Charger Unit, Standby
Mode cannot be entered using the On/Off Push Button on the front panel of the EVO Inverter-Charger
Unit