SAMLEX AMERICA INC. | 31
4.1.3.1 "Select Parameter" Menu Map for Parameter Group 1: CHARGE CURVE
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* B U L K C U R R E N T
2 0 A
Screen
No. 1
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* A B S O R P V O L T A G E
1 4 . 4 0 V
Screen
No. 2
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* E Q U A L I Z E V O L T A G E
1 4 . 4 0 V
Screen
No. 3
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* C O M P E N S A T E
4 m V /
°
C / C e l l
Screen
No. 5
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* B A T T O V E R V O L T
1 6 . 0 0 V
Screen
No. 6
ð ð ð ð
ð ð ð ð
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* F L O A T V O L T A G E
1 3 . 5 0 V
Screen
No. 4
ð
ð
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* R E S E T V O L T A G E
1 4 . 0 0 V
Screen
No. 7
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* L O W V O L T A L A R M
1 1 . 0 0 V
Screen
No. 8
ð ð
ð ð
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* B A T T L O W V O L T A G E
1 0 . 5 0 V
Screen
No. 9
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* L V D E T E C T T I M E
1 0 s e c
Screen
No. 10
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* L V C U T O F F T I M E
1 2 0 0 s e c
Screen
No. 11
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* M O D E
0 = N o r m a l
Screen
No. 13
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* O N L I N E O P T I O N
0 = O p t i o n 1
Screen
No. 14
ð ð ð ð
ð ð ð ð
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* E Q U A L I Z E - 4 S T A G E S
0 = N o
Screen
No. 12
ð
ð
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* R E S E T T O B U L K
1 2 . 0 0 V
Screen
No. 15
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* G S D E T E C T T I M E
1 0 s e c
Screen
No. 16
ð ð
ð ð
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* G E N O N T I M E
6 0 m i n
Screen
No. 17
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* G E N O F F D E L A Y
6 0 m i n
Screen
No. 18
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* A B S O R P T I M E
6 0 m i n
Screen
No. 19
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* C H A R G I N G P R O F I L E
0 = 3 S t a g e A d a p t i v e
Screen
No. 21
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* B A T T E R Y T Y P E
0 = L e a d A c i d
Screen
No. 22
ð ð ð ð
ð ð ð ð
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* A B S O R P E X I T A M P S
4 A
Screen
No. 20
ð
ð
SECTION 4 | Parameter Setup
NOTES:
1. Value shown in the 4
th
line of the display screen is the default / factory pre-set values (EVO-1212F / 1212F-HW in
this case). Refer to Table 4.3 (Section 4.4.1) for the default / factory pre-set values and additional programming
details for the other Models
2. Asterisk sign * in the beginning of the 3
rd
line of the display screen points that the parameter shown in this line
will be selected for further programming when the Enter Key is pressed
3. Use Up ñ and Down ò Keys to navigate to the desired screen.
Up Key
Down Key
ð
ð
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* S A F E C H A R G I N G
0 m i n
S e l e c t P a r a m e t e r
C H A R G E C U R V E
* E X T . C H A R G E R
1 = N o t a f f e c t
ð
ð
Screen
No. 23
Screen
No. 24
Fig 4.2 "Select Parameter" Menu Map for Parameter Group 1 - CHARGE CURVE